(Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying steel entry doors and their installation. The specifier needs to edit these guide specifications to fit the needs of each specific project. Contact a JELD-WEN® representative to assist in appropriate product selections. Throughout the guide specification, there are Specifier Notes to assist in the editing of the file.

References have been made within the text of the specification to MasterFormat 2004 Section numbers and titles, specifier needs to coordinate these numbers and titles with sections included for the specific project. Brackets []; “AND/OR”; and “OR” have been used to indicate when a selection is required. Some options may require additional lead-time, if this is a consideration, contact a JELD-WEN® representative for assistance.)

SECTION 08 11 26.00

STEEL DOORS

JELD-WEN® [Contours][Energy Saver][FiniShield][Gladiator] Steel Doors

PART 1 - GENERAL

1.1SECTION INCLUDES

  1. Steel Entrance Doors[, Transoms][ and Sidelights]
  2. [Prehung Hardwood Systems]
  3. [Glazing]

1.2REFERENCES

  1. American Architectural Manufacturer Association (AAMA)

AAMA 1304; Voluntary Specification for Forced Entry Resistance of Side-Hinged Door Systems.

(Specifier Note: In applications where hurricane resistance is not required DELETE AAMA 506 reference.)

AAMA 506; Voluntary Specifications for Hurricane and Impact and Cycle Testing of Fenestration Products.

  1. ASTM International

ASTM E283; Standard Test Method for Determining Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors Under Specified Pressure Differences Across the Specimen

ASTM E330; Standard Test Method for Structural Performance of Exterior Windows, Doors, Skylights and Curtain Walls by Uniform Static Pressure Difference

ASTM E331; Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Uniform Static Air Pressure Difference

ASTM E547; Standard Test Method for Water Penetration of Exterior Windows, Skylights, Doors, and Curtain Walls by Cyclic Static Air Pressure Difference

(Specifier Note: In applications where hurricane resistance is not required DELETE ASTM E 1886 and E 1996 references.)

ASTM E 1886; Standard Test Method for Performance of Exterior Windows, Curtain Walls, Doors, and Impact Protective Systems Impacted by Missile(s) and Exposed to Cyclic Pressure Differentials

ASTM E 1996; Standard Specification for Performance of Exterior Windows, Curtain Walls, Doors and Impact Protective Systems Impacted by Windborne Debris in Hurricanes

(Specifier Note: DELETE Florida FBC information if project is not within the High Velocity Hurricane Zone)

  1. FloridaBuilding Code

FBC Section 1626: High Velocity Hurricane Zones – Impact Tests for Windborne Debris

  1. National Fenestration Rating Council (NFRC)

NFRC 100; Procedure for Determining Fenestration Thermal Properties

NFRC 200; Solar Heat Gain Coefficient and Visible Transmittance

  1. National Fire Protection Association (NFPA)

NFPA 252: Standard Methods of Fire Tests of Doors Assemblies.

(Specifier Note: DELETE Florida TAS information if project is not within the High Velocity Hurricane Zone.)

  1. SouthFloridaBuilding Code Impact Test Procedures (Miami-Dade TAS)

TAS 201; Impact Test Procedures

TAS 202; Criteria for testing Impact and Non-Impact Resistant Building Envelope Components using Uniform Static Air Pressure

TAS 203; Criteria for testing Products Subject to Cyclic Wind Pressure Loading

  1. Underwriters Laboratories, Inc. (UL)

UL 10B: Standard for Fire Test of Door Assemblies.

UL 10C:Standard for positive Pressure Fire Tests of Doors Assemblies.

H.UniformBuilding Code Standard 7-2 (UBC).

1.UBC 7-2 (1994): Fire Tests of Door Assemblies. (Note: Neutral pressure testing standard).

2.UBC 7-2 (1997): Fire Test of Door Assemblies. (Note: Positive pressure testing standard).

  1. Underwriters’ Laboratories of Canada (ULC)

CAN4-S104: Standard Method for Fire Tests of Door Assemblies.

(Specifier Note: DELETE reference below when Auralast frame is not specified.)

  1. Window & Door Manufacturers Association (WDMA)

WDMA I.S.4; Water Repellent Preservative Non-Pressure Treatment for Millwork.

1.3DESIGN REQUIREMENTS

  1. Provide doors capable of complying with requirements indicated, based on testing manufacturer’s doors that are representative of those specified.

(Specifier Note: DELETE Fire-Rated Door Assemblies requirement if fire rated assemblies are not specified. SELECT desired code references. When retaining UL reference, SELECT UL 10B (neutral-presure) or 10C (positive-pressure).)

  1. Fire-Rated Door Assemblies: Fire door assemblies shall meet or exceed fire-protection ratings indicated when tested in accordance with [NFPA 252] [UL 10[B][C]][CAN-4S104] [and] [UBC 7-2].

(Specifier Note: Include door design pressure (DP) ratings as part of the performance requirements. Required DP will vary dependent on project site, the location in the building and door size. Coordinate DP with the Structural Engineer. DP ratings and related door size and style are available at or by contacting a JELD-WEN® representative.)

  1. Structural Requirements – Provide doors capable of complying with requirements indicated:

Design pressure: [Insert value] [As indicated on drawings]

(Specifier Note: DELETE Impact Resistance requirement if products will not be used in a high velocity hurricane zone or will be used in conjunction with another type of approved hurricane protection device.)

  1. Impact (Windborne-Debris) Resistance

Doors capable of resisting impact from windborne debris, when tested in accordance with ASTM E1886, ASTM E1996 and AAMA 506.

AND/OR

Provide doors that have been tested in accordance with FBC Section 1626.

Provide windows that have been tested in accordance with TAS 201, TAS 202, and have received NOA from Miami-Dade Code Officials.

(Specifier Note: Include NFRC ratings as part of the performance requirements. NFRC ratings qualifying for the Energy Star program are based on the performance of the whole door assembly. Qualifying doors vary to fit the needs of different regions throughout the country. NFRC ratings and related JELD-WEN® door size and styles are available at or by contacting a JELDWEN® representative.)

  1. NFRC Requirements – Provide doors capable of complying with the following total door ratings:

U-Factor: [Insert value] in accordance with NFRC 100.

Solar Heat Gain Coefficient (SHGC): [Insert value] in accordance with NFRC 200.

1.4SUBMITTALS

  1. Refer to Section [01 33 00 Submittal Procedures] [Insert section number and title].
  2. Product Data: Submit door manufacturer current product literature, including installation instruction.
  3. Samples: Provide finish samples for all products.
  4. Quality Assurance Submittals

(Specifier Note: DELETE Design Data, Test Reports submittal requirements when propriety specification is used and can be held. MAINTAIN Design Data, Test Reports submittal requirement when other products may be submitted as substitution.)

Design Data: Provide manufacturer test report numbers indicating product compliance with indicated requirements.

Manufacturer Instructions: Provide manufacturer’s written installation instructions.

  1. Closeout Submittals

Refer to Section [01 78 00 Closeout Submittals] [Insert section number and title].

1.5DELIVERY, STORAGE AND HANDLING

  1. Refer to Section [01 60 00 Product Requirements] [Insert section number and title].
  2. Deliver doors, materials and components in manufacturer’s original, unopened, undamaged containers with identification labels intact.
  3. Store doors as recommended by manufacturer.

1.6WARRANTY

  1. Refer to Section [01 78 36 Warranties] [Insert section number and title].

(Specifier Note: DELETE warranty information not specific to project.)

  1. Manufacturer standard warranty indicating that doors will be free from material and workmanship defects from the date of substantial completion for the time periods indicated below:

Door System : 10 Years.

(Specifier Note: DELETE warranty below when Auralast frame is not specified.)

Auralast Frame: Lifetime.

PART 2 - PRODUCTS

(Specifier Note: Product Information is proprietary to JELD-WEN®. If additional products are required for competitive procurement, contact JELD-WEN® for assistance in listing competitive products that may be available.)

2.1MANUFACTURER

  1. JELD-WEN® Exterior Doors; 3305 Lakeport Blvd; Klamath Falls, OR 97601, USA; Phone 877.535.3462, fax 541.882.3455; website

(Specifier Note: SELECT Basis of Design from styles listed below. Contact a JELD-WEN® representative to assist in appropriate product selections.)

  1. Basis of Design: Doors are based on the JELD-WEN®’s [Contours] [Energy Saver] [FiniShield]] [Gladiator] Steel Doors.

(Specifier Note: Select from the following for Mahogany appearance.)

1.Contours[insert design #].

1.Energy Saver [insert design #].

1.Finishield [insert design #].

1.Gladiator [insert design #].

(Specifier Note: Select from the following for Oak appearance.)

2.2MATERIALS

(Specifier Note: AuraLast™ is a trademark preservative treatment by JELD-WEN® and is distinguished from traditional preservation methods by its minimum treatment penetration of 92%. SELECT option if desired. COORDINATE with other paragraphs.)

  1. Wood Frames: Western Pine[, preservative treated with AuraLast™ in accordance with WDMA I.S.4.].

(Specifier Note: SELECT 24-gauge when Contours or Energy Saver doors are specified. SELECT 25-gauge for Finishield or Gladiator.)

  1. Steel Skins: [24][25]-gauge cold-rolled galvanized steel.

(Specifier Note: Wood edge construction is standard. SELECT Steel Edge Construction when fire rated Contours or Energy Saver doors are specified.)

  1. Stiles and Rails

Wood Edge Construction: 1 inch Laminated Veneer Lumber (LVL).

OR

Steel Edge Construction: 22-gauge continuous roll-formed steel.

  1. Core: Custom-fitted Polystyrene.

2.3STEEL ENTRANCE DOORS[, TRANSOM][ AND SIDELIGHTS]

(Specifier Note: Fire rating options below are available only when Contours or Energy Saver doors are specified. For true fire protection these doors must be used with certified frames and hardware.)

  1. Thickness: 1-3/4 inch[ with [20][90] minute fire rating].

(Specifier Note: Wood edge construction is standard. SELECT Steel Edge Construction when fire rated Contours or Energy Saver doors are specified.)

  1. Edge Construction: [Wood] [Steel].
  2. Door Design

(Specifier Note: SELECT Smooth when Contours, Energy Saver, or Gladiator doors are specified. SELECT Textured for FiniShield.)

Door Surface: [Smooth][Textured].

Door Shape: Squared Top.

Door Style: [Solid] [Paneled and Glass].

(Specifier Note: SELECT from following paragraph when Contours doors are specified.)

Face Pattern: [3-Panel][Sunburst][6-Panel][8-Panel][9-Panel].

(Specifier Note: SELECT from following paragraph when Energy Saver doors are specified.)

Face Pattern: [4-Panel][Cathedral][6-Panel][8-Panel][2-Panel][2-Panel Arch Top][2-Panel V-Groove Arch Top].

(Specifier Note: SELECT from following paragraph when FiniShield doors are specified.)

Face Pattern: [3-Panel] [Sunburst] [6-Panel] [8-Panel] [8-Panel Arch Top] [9-Panel].

(Specifier Note: SELECT from following paragraph when Gladiator doors are specified.)

Face Pattern: [3-Panel] [Sunburst] [6-Panel] [9-Panel].

(Specifier Note: DELETE paragraph and subparagraphs below if sidelights are not part of project.)

  1. Sidelights

Size: [Elliptical] [1/4] [1/2] [3/4] [Full] lite.

Style: Match door style.

(Specifier Note: DELETE paragraph below if transoms are not part of project.)

  1. Transoms

Shape: [Rectangle] [Compound radius] [Half-Round].

(Specifier Note: SELECT Beaded when Contours doors are specified. SELECT Standard for all others.)

  1. Sticking Profile: [Standard] [Beaded].

(Specifier Note: SELECT last option when FiniShield doors are specified. SELECT first option for all others.)

  1. Finish: [Two-coats, low-sheen, baked-on enamel primer] [Prefinished 7mil layer of textured vinyl].

(Specifier Note: Doors are available as prehung or slabs are with hinge and lockset prep. RETAIN one of two paragraphs below.)

  1. Hardware: None. [Prep door for owner supplied hinge and lockset.]

OR

  1. Hardware Finish: [Antique Brass] [Brass] [Satin Nickel].

(Specifier Note: All doors are available as a prehung system, which includes the door slab, frame, hardware and all necessary components. DELETE entire article if not desired.)

2.4PREHUNG HARDWOOD SYSTEMS

  1. Profile: [System 01, Single Door] [System 03, One Door, One Sidelight] [System 04, One Door, Two Sidelights]

(Specifier Note: Solid pine Auralast wood provides superior protection against wood decay, water saturation and termites. Coordinate with warranty paragraph above.)

  1. Jamb: Solid pine [Auralast] wood.

Profile: [Solid Flat] [Rabbeted].

Width: [4-9/16 inch] [5-1/4 inch] [6-9/16 inch].

  1. Casing: Brickmould
  2. Hinges: Solid brass concealed-bearing.

(Specifier Note: First option listed is standard.)

Finish: [Zinc Dichromate] [Antique Brass] [Lite Brass] [Oil-Rubbed Bronze] [Bright Chrome] [Brushed Chrome] [Antique Nickel] [Satin Nickel].

  1. Sills: Aluminum with [Polished Aluminum] [Brass] [Oil-Rubbed Bronze] Finish.

(Specifer Note: DELETE article below if solid door and no sidelights or transoms are specified.)

2.5GLAZING

  1. Glass Inserts: JELD-WEN Basis of Design Style, [Avant] [Bellflower] [Beveled Elegance] [Bristol] [Cadence] [Casa Blanca] [Catalina] [Cirrus] [Cut Crystal] [Entropy] [Expressions] [Greenfield] [Heirlooms] [Impressions] [Jacinto] [Legacy Master] [Madison] [Majestic] [Mediterranean] [Monterey] [Nouveau] [Oak Park] [Paris] [Prairie Bevel] [Radiant Hues] [Simplicity] [Teton] [Topaz] [Trace] [Tripoli ] [Veranda].
  2. Transom Glazing: [Match Glass Insert Style] [Clear][Low-E].

2.6CONSTRUCTION ACCESSORIES

(Specifier Note: Construction Accessories compatible with doors and required installation may be specified in this section or in related sections. COORDINATE with related sections to not duplicate information.)

  1. Flashing

Refer to Section [04 20 00 Unit Masonry] [07 60 00 Flashing and Sheet Metal] [Insert section number and title].

  1. Sealants

Refer to Section [07 92 00 Joint Sealants] [Insert section number and title].

OR

(Specifier Note: For sealants specified within this section list recommended products.)

Provide manufacturer recommended sealants maintain watertight conditions.

Products:

  1. [Insert products and manufacturer]

2.7FABRICATION

  1. One-piece of polystyrene is custom fitted in standard wood stile and rail frame. Back of steel skin is coated with epoxy primer before attachment to core and frame.

PART 3 - EXECUTION

3.1GENERAL

  1. Install doors in accordance with manufacturer’s installation guidelines and recommendations.

3.2EXAMINATION

  1. Inspect door prior to installation.
  1. Inspect rough opening for compliance with door manufacturer recommendations. Verify rough opening conditions are within recommended tolerances.

(Specifier Note: DELETE article below if prehung system is not specified.)

3.3INSTALLATION

  1. Install jamb assembly.

Caulk sill along outside edge and ½ inch in from edge of subfloor.

Set door unit into center of opening and tack in place.

Shim hinge then latch side jambs straight. Inspect jamb for square, level and plumb.

(Specifier Note: DELETE subparagraph below if no sidelights are specified.)

Shim and fasten top of unit where sidelight joins door jamb.

Fasten hinge side jamb to studs.

Verify door opens freely and weatherstrip meets door evenly.

Verify door sweep contacts threshold evenly.

Fasten latch side jamb to studs.

(Specifier Note: DELETE installation paragraph below if not project specific.)

  1. Install transom.

Apply caulk on top of door head jamb.

Set transom jamb on door head jamb and fasten.

Shim transom straight. Inspect transom for square, level and plumb.

Fasten transom to studs.

  1. Caulk outside perimeter of door unit between brickmold and wall face, along front side of threshold, and between jamb sides and threshold.

3.4PROTECTION

  1. Protect installed doors from damage.

3.5SCHEDULES

(Specifier Note: Below are sample schedules that require editing for specific project. When a single type of door is utilized on a project, Specifier may elect to delete the schedule in its entirety. When Schedules are included on the drawings, schedule should be deleted from the specification.)

  1. Door Type A

Basis of Design:Contours

Thickness:1-3/4”

Steel Thickness:24-gauge

Fire Rating:none

Edge Construction:Wood

Door Design

  1. Surface:Smooth
  2. Shape:Squared
  3. Style:Paneled and Glass
  4. Face Pattern:3-Panel

Sidelights:Full

Transom:Rectangle

Sticking Profile:Beaded

Finish:Baked Enamel Primer

Hardware:Satin Nickel

Profile:System 03

Jamb:Solid Pine

  1. Profile:Solid Flat
  2. Width:4-9/16”

Casing:Brickmould

Hinges:Satin Nickel

Sill:Aluminum with Polished Aluminum

Glass Inserts:Blakely

  1. Door Type B

Basis of Design:FiniShield

Thickness:1-3/4”

Steel Thickness:25-gauge

Fire Rating:none

Edge Construction:Wood

Door Design

  1. Surface:Textured
  2. Shape:Squared
  3. Style:Paneled and Glass
  4. Face Pattern:6-Panel

Sidelights:1/2

Transom:None

Sticking Profile:Standard

Finish:Prefinished Vinyl

Hardware:Brass

Profile:System 03

Jamb:Solid Pine Auralast

  1. Profile:Solid Flat
  2. Width:4-9/16”

Casing:Brickmould

Hinges:Lite Brass

Sill:Aluminum with Brass

Glass Inserts:Avalon

END OF SECTION

Project Name/Project Number/12-May-11 08 11 26.00.[PREMIUM][BUILDERS] - 1STEEL DOORS