DuraSpan Installation Instructions without Track System
DuraSpan Installation Instructions Without Track System
Pre-Installation
1. Know What Components You Received From the Vendor
- Open and identify shipped materials
- Look for production drawings to verify against
2. Verify Site Height and Width at Installation Site
- Identify points where mounting hardware will attach to existing application
- Usually the track system itself will take 2 inches of height off curtain
- Verify height of curtain to point of attachment
- Curtain should hang ½ to 1 inch above ground
- Allow for 2 inches for track system
- Within the first 24 hours of hanging, the curtain will stretch a small amount
- Note: The warmer the temperature, the taller the curtain may become
- This re-proportioning may require a new height adjustment to the mounting hardware prior to the actual installation
- Curtain vendor does not provide any mounting hardware: bolts, nuts, angle iron, etc.
3. Verify Shipped Components
- Curtain
- Know shipped curtain height
- Know shipped curtain width
- Know the number of panels and their installation sequence
- Get ceiling angle iron (Provided by installer)
- Supply angle iron to attach to side walls (If required, provided by installer)
- Supply vertical stiffeners (If required, provided by installer)
- Pockets typically pre-attached to curtain
- Usually 1 or 2 inch pipe
- To stabilize curtain, attach at floor and ceiling
- Find personnel door materials (Optional)
- Door frame and vinyl strips (See attachment)
- Find traffic door materials (Optional)
- Door frame and vinyl strips (See attachment)
4. Installation
- Installer must identify and supply materials to attach curtain wall to
- Re-verify distance, support materials (i.e. angle iron)
- Make any adjustments to height prior to installation
- Attach curtain to support material (i.e. angle iron)
- Refer to vendor production drawing
- Panels are typically numbered; begin with number one and continue hanging from there
- Make sure all panel to panel attachments are secured completely
- Hitting floor with ½ to 1 inch of floor excess
- Address attachment of extreme ends of curtain to wall (Optional)
- Either tek screw or Velcro to installed angle iron or attach directly to wall
- Install vertical stiffeners (Optional)
- Pockets must exist on curtain
- Run piping through vertical pocket, attach at floor and ceiling
- Install personnel door (Optional)
- Use included attachment: Installing a Personnel Door
- Install traffic door (Optional)
- Use included attachment: Installing a Traffic Door
- Make all adjustments