SECTION 11 76 00

OPERATING ROOM EQUIPMENT AND MANAGEMENT SYSTEMS

Display hidden notes to specifier. (Don't know how? Click Here)

Copyright 2017 - 2018 ARCAT, Inc. - All rights reserved

** NOTE TO SPECIFIER ** Hill-Rom Architectural Products; operating room equipment and management systems and health care industry products and solutions.
This section is based on the products of Hill-Rom Architectural Products, which is located at:
1069 State Route 46 E.
Batesville, IN 47006
Toll Free Tel: 812-934-7777
Fax: 812-934-8189
Email: request info ()
Web: https://construction.hill-rom.com
[ Click Here ] for additional information.
Hill-Rom is a leading worldwide manufacturer and provider of medical technologies and related services for the health care industry, including patient support systems, safe mobility and handling solutions, non-invasive therapeutic products for a variety of acute and chronic medical conditions, medical equipment rentals, surgical products and information technology solutions. Hill-Rom's comprehensive product and service offerings are used by health care providers across the health care continuum and around the world in hospitals, extended care facilities and home care settings to enhance the safety and quality of patient care.
Hill-Rom: Enhancing outcomes for patients and their caregivers. (r)

1 GENERAL

1.1   SECTION INCLUDES

** NOTE TO SPECIFIER ** Delete items below not required for the project.

1.1.1   Operating room equipment and management systems including the following:

1.1.1.1   Equipment management systems: Booms.

1.1.1.2   Video cameras.

1.1.1.3   Monitor holders.

1.1.1.4   Operating room tables.

1.1.1.5   Operating room surgical lights.

1.2   RELATED SECTIONS

1.2.1   Section 10 25 13 - Headwalls, Headboards and Bed Locators.

1.2.2   Section 11 76 00 - Medical Arms and Columns.

1.2.3   Section 11 73 00 - Patient Care Equipment.

1.2.4   Section 27 52 00 - Health Care Communications and Monitoring Systems.

1.3   REFERENCES

** NOTE TO SPECIFIER ** Delete references from the list below that are not actually required by the text of the edited section.

1.3.1   European Commission (EEC):

1.3.1.1   93/42/EEC Appendix IX.

1.3.2   International Electrotechnical Commission (IEC):

1.3.2.1   IEC/ANSI 60529 - Degrees of protection provided by enclosures (IP Code).

1.3.2.2   IEC 60601-1/EN 60601-1 - Medical Electrical Equipment - Part 1: General requirements for basic safety and essential performance.

1.3.2.3   IEC 60601-1-2/EN 60601-1-2 - Medical Electrical Equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests.

1.3.2.4   IEC 60601-2-46/EN 60601-2-46 - Medical Electrical Equipment - Part 2-46: Particular requirements for the basic safety and essential performance of operating tables.

1.3.3   National Fire Protection Association (NFPA):

1.3.3.1   NFPA 70 - National Electrical Code.

1.3.3.2   NFPA 99 - Health Care Facilities Code.

1.3.4   European Medical Devices Directive (MDD):

1.3.4.1   MDD Appendix I - Essential Requirements.

1.3.4.2   MDD Appendix VII - EC Declaration of Conformity.

1.4   SUBMITTALS

1.4.1   Submit under provisions of Section 01 30 00 - Administrative Requirements.

1.4.2   Product Data: Manufacturer's data sheets on each product to be used, including:

1.4.2.1   Source quality certificates.

1.4.2.2   Pre-Installation Manual: Preparation instructions and recommendations.

1.4.2.3   Installation Manual: Storage and handling requirements and recommendations.

1.4.2.4   Installation Manual: Installation methods.

1.4.2.5   Service Manual: Maintenance and operations data.

1.4.3   Shop Drawings: Include system components, utility requirements and connections, relationship with adjacent construction. Include required clearances and access for servicing.

1.4.3.1   Communications wire labeling schedules.

1.4.3.2   Communications wiring diagrams.

1.4.3.3   Plans and elevations of telecommunications room.

1.4.3.4   Pathways.

1.4.3.5   Access points.

1.4.3.6   Grounding.

1.4.3.7   MEP systems.

1.5   QUALITY ASSURANCE

1.5.1   Regulatory Requirements: Comply with requirements of authorities having jurisdiction and applicable codes at the location of the project.

1.5.2   Manufacturer Qualifications: Minimum 5 years' experience manufacturing similar products.

1.5.3   Installer Qualifications: Minimum 2 years' experience installing similar products.

1.6   DELIVERY, STORAGE, AND HANDLING

1.6.1   Deliver and store products in manufacturer's unopened packaging bearing the brand name and manufacturer's identification until ready for installation.

1.6.2   Comply with manufacturer's recommendations. Handle materials to avoid damage.

1.7   PROJECT CONDITIONS

1.7.1   Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install products under environmental conditions outside manufacturer's recommended limits.

1.8   WARRANTY

1.8.1   Provide manufacturer's standard limited warranty.

2 PRODUCTS

2.1   MANUFACTURERS

2.1.1   Acceptable Manufacturer: Hill-Rom Architectural Products, which is located at: 1069 State Route 46 E.; Batesville, IN 47006; Toll Free Tel: 812-934-7777; Fax: 812-934-8189; Email: request info (); Web: https://construction.hill-rom.com

** NOTE TO SPECIFIER ** Delete one of the following two paragraphs; coordinate with requirements of Division 1 section on product options and substitutions.

2.1.2   Substitutions: Not permitted.

2.1.3   Requests for substitutions will be considered in accordance with provisions of Section 01 60 00 - Product Requirements.

** NOTE TO SPECIFIER ** Delete if not required. Delete features not required.

2.2   EQUIPMENT MANAGEMENT SYSTEMS: BOOMS

2.2.1   Basis of Design: Hill-Rom Architectural Products, Trumpf Medical; Model: TruPort Supply Unit. Flexible, modular, fully configurable, and ergonomic design, flush-fitting surfaces, with intelligent plug-in components.

2.2.2   Standards:

2.2.2.1   NFPA 70.

2.2.2.2   NFPA 99.

** NOTE TO SPECIFIER ** The MPC rail in the subparagraph below is optional. It is a low-voltage power rail and BUS system which allows additional features and functionality to be added to the Supply unit.

2.2.3   MPC Rail: 25 V rail power and integrated BUS system.

2.2.3.1   LED lights.

2.2.3.2   Control handles.

2.2.4   Mounting System:

2.2.4.1   110106 - 8 inch (203 mm) or 12 inch (305 mm) interstitial span

2.2.4.2   110107 - 14 inches (356 mm) to 47.25 inches (1,200 mm) interstitial span.

2.2.4.3   110108 - 47.25 inches (1,200 mm) to 59 inches (1,498 mm) interstitial span.

2.2.5   Support Arms:

2.2.5.1   Medium Load:

2.2.5.1.1   1200mm (47 inches)

2.2.5.1.2   1465mm (58 inches)

2.2.5.1.3   1730mm (68 inches)

2.2.5.1.4   1995mm (79 inches)

2.2.5.1.5   2260mm (89 inches)

2.2.5.1.6   2430mm (96 inches)

2.2.5.1.7   2600mm (102 inches)

2.2.5.2   Heavy Load:

2.2.5.2.1   1200mm (47 inches)

2.2.5.2.2   1465mm (58 inches)

2.2.5.2.3   1730mm (68 inches)

2.2.5.2.4   1995mm (79 inches)

2.2.5.2.5   2260mm (89 inches)

2.2.5.2.6   2430mm (96 inches)

2.2.5.2.7   2600mm (102 inches)

2.2.5.3   Vertically Articulating:

2.2.5.3.1   1600mm (63 inches)

2.2.5.3.2   1865mm (73 inches)

2.2.5.3.3   2130mm (84 inches)

2.2.5.3.4   2300mm (91 inches)

2.2.5.4   Brake System:

2.2.5.4.1   Friction.

** NOTE TO SPECIFIER ** MPC Rail is required for the following two subparagraphs.

2.2.5.4.2   Electro-pneumatic.

2.2.5.4.3   Electro-magnetic.

2.2.6   Support Head:

** NOTE TO SPECIFIER ** MPC Rail is required for the optional motorized lifting system. Delete what is not required.

2.2.6.1   L: 12 x 12 inches (310 mm x 310 mm).

** NOTE TO SPECIFIER ** For a maximum length of 68.9 in (1,750 mm), in 9.8 in (250 mm) Consult a Hill-Rom representative. Delete lengths not required.

2.2.6.1.1   Length: 9.8 inches (250 mm).

2.2.6.1.2   Length: 19.7 inches (500 mm).

2.2.6.1.3   Length: 29.5 inches (750 mm).

2.2.6.1.4   Length: 39.4 inches (1000 mm).

2.2.6.1.5   Length: 49.2 inches (1250 mm).

2.2.6.1.6   Length: 59.0 inches (1500 mm)

2.2.6.1.7   Length: 19.7 inches (500 mm). Horizontal

2.2.6.1.8   Length: 29.5 inches (750 mm). Horizontal

2.2.7   Supply Modules Flexibility: Modules can be reorganized on the support head to meet specific needs and functionality.

2.2.7.1   Low voltage (e.g, data).

2.2.7.2   Gas.

2.2.7.3   Electric power.

2.2.8   Workplace Components:

2.2.8.1   Tool-less mounting with click mechanism.

** NOTE TO SPECIFIER ** MPC Rail is required for electrical components.

2.2.8.2   Electronic Components: MPC rail required.

2.2.9   AmbientLine Modules: MPC Rail required.

** NOTE TO SPECIFIER ** MPC Rail is required if an AmbientLine(tm) desk is required.

2.2.9.1   AmbientLine Desk: Rotatable LED Light.

2.2.9.2   AmbientLine Drawer Light.

2.2.10   Shelves and Drawers:

2.2.10.1   Load Capacity: 176 pounds (80 kg).

2.2.10.1.1   430mm x 260mm (17 inches x 10 inches).

2.2.10.1.2   430mm x 480mm (17 inches x 19 inches).

2.2.10.1.3   530mm x 480mm (21 inches x 19 inches).

2.2.10.1.4   630mm x 480mm (25 inches x 19 inches).

2.2.10.1.5   730mm x 480mm (29 inches x 19 inches).

2.2.10.2   Load Capacity with Shelf Extension: 110 pounds (50 kg).

2.2.10.2.1   Additional 70mm (2.8 inches) to shelf options.

2.2.11   Sub System Head Components:

2.2.11.1   Sub system head for Dock on Trolley.

2.2.11.2   Sub system head for Quad Suction Canister Holder.

** NOTE TO SPECIFIER ** Delete if not required. Delete features not required.

2.3   VIDEO CAMERAS

2.3.1   Basis of Design: Hill-Rom Architectural Products, Trumpf Medical; Model: TruVidia Camera Systems.

2.3.1.1   Completely Modular, Video Solution: Separate infrastructure with digital HD video output. Fully configurable to meet the needs of OR specialties.

2.3.2   Wireless Camera:

2.3.2.1   Basis of Design: Hill-Rom Architectural Products; Trumpf Medical: Model: TruVidia Wireless Camera.

2.3.2.2   Picture Sensor: 1 to 2.8 inch CMOS.

2.3.2.3   Resolution: 2 million pixels

2.3.2.4   Supported Video Formats: 1080p50, 1080p30,1080p25, 720p60, and 720p50.

2.3.2.5   Picture Format: 16:9.

2.3.2.6   Zoom Factor:

2.3.2.6.1   Optical 10x.

2.3.2.6.2   Digital 12x.

2.3.2.7   Ratio: 16:9.

2.3.2.8   Lens:

2.3.2.8.1   Focal Length, f: 0.15 to 1.5 in (3.8 to 38 mm).

2.3.2.8.2   Maximum Aperture Diameter, F: .071 to .134 in (1.8 to 3.4 mm).

2.3.2.9   Signal/Noise Ratio: Greater than 50 dB.

2.3.2.10   Picture Stabilization: Standard.

2.3.2.11   White Balance: Automatic and manual.

2.3.2.12   Motorized Picture Rotation: Continuous rotation.

2.3.2.13   Picture Freeze: Digital.

2.3.2.14   Auto Exposure: Automatic and manual.

2.3.2.15   Focusing: Automatic and manual.

2.3.2.16   Weight: 1.9 lbs. (0.85 kg).

2.3.2.17   Broadcast:

2.3.2.17.1   Video Transmission: 5 GHz, AES II 128 bit encryption.

2.3.2.17.2   Maximum Number of Cameras per OR: 1.

2.3.2.17.3   Receiver: Desk top or wall attachment. for wireless interface without data cables. Maximum number of receivers per cameras: 8.

2.3.2.17.4   Audio: Unidirectional.

2.3.2.18   Flexible Data Storage: Images may be saved to USB memory devices during procedures.

2.3.2.19   Wireless Receiver:

2.3.2.19.1   Video: 5 GHz, AES II 128 bit encryption.

2.3.2.19.2   Control: 802.11 a/b/g/n wi-fi (2.4 GHz and 5 GHz) WPA 2 personal encrypted.

2.3.2.19.3   System Latency: Less than 1 ms.

2.3.2.19.4   Transmission Range: 10 m.

2.3.2.19.5   Power Supply: 100 to 240 VAC, 50 to 60 Hz. 0.5A maximum.

2.3.2.19.6   Dimensions (LxWxH): 16.9 x 8.8 x 1.7 inches (428 x 225 x 44 mm).

2.3.2.19.7   Weight (excluding cable): 4.0 lbs. (1.8 kg).

2.3.2.19.8   Fixation: VESA 100.

2.3.2.19.9   Video Outputs:

2.3.2.19.9.1   1 x 3G-SDI (HD- SDI switchable).

2.3.2.19.9.2   1 x DVI (with adaptor).

2.3.2.20   Controls: TruRemote Integration Control System: Touchscreen technology.

2.3.2.20.1   Wall Station:

2.3.2.20.1.1   Dimensions (LxWxH): 11.4 x 7.6 x 2.6 inches (290 x 225 x 44 mm).

2.3.2.20.1.2   Weight: 5.7 lbs. (2.56 kg).

2.3.2.20.1.3   Integrated Power Supply: 100 to 240 VAC. 50 to 60 Hz.

** NOTE TO SPECIFIER ** Available only in certain countries. Verify with manufacturer before including.

2.3.2.20.2   Mobile Tablet:

2.3.2.20.2.1   Dimensions (LxWxH): 9.8 x 0.7 x 5.9 inches (250 x 17 x 150 mm).

2.3.2.20.2.2   Bumper Material: PU.

2.3.2.20.2.3   Weight: 1.5 lbs. (0.7 kg).

2.3.2.20.2.4   Protection Class: IP67.

** NOTE TO SPECIFIER ** Available only in certain countries. Verify with manufacturer before including.

2.3.2.20.3   Dock Desk:

2.3.2.20.3.1   Dimensions (LxWxH): 0.7 x 0.4 x 0.1 inch (250 x 110 x 25 mm)

2.3.2.20.3.2   Weight: 1.3 lbs. (0.6 kg).

2.3.2.20.3.3   External Power Supply: 100 to 240 VAC 50 to 60 Hz.

2.3.2.20.3.4   Protection class IP22.

2.3.3   Wired HD Camera:

2.3.3.1   Basis of Design: Hill-Rom Architectural Products, Trumpf Medical; Model: TruVidia HD-Camera.

2.3.3.1.1   HD technology provides reliable streaming of video data with pixel density five times greater than analog.

2.3.3.2   Resolution: 2 million pixels.

2.3.3.3   Supported Video Formats: 1080 lines interlaced (HD-SDI) / Progressive (DVI).

2.3.3.4   Picture Format: 16:9.

2.3.3.5   Zoom Factor:

2.3.3.5.1   Optical 10x.

2.3.3.5.2   Digital 12x.

2.3.3.6   Ratio: 16:9.

2.3.3.7   Lens:

2.3.3.7.1   Focal Length f: .20 to 2.0 in (5.1 to 51 mm).

2.3.3.7.2   Maximum Aperture Diameter F: .071 to .083 in (1.8 to 2.1 mm).

2.3.3.8   Signal to Noise Ratio: Greater than 50 dB.

2.3.3.9   Picture Stabilization: Standard.

2.3.3.10   White Balance: Automatic and manual.

2.3.3.11   Motorized Picture Rotation: Continuous rotation.

2.3.3.12   Picture Freeze: Digital.

2.3.3.13   Auto Exposure: Automatic and manual.

2.3.3.14   Focusing: Automatic and manual.

2.3.3.15   Weight: 1.9 lbs. (0.85 kg).

2.3.3.16   Video Signal Outputs:

2.3.3.16.1   1 x HD-SDI.

2.3.3.16.2   1 x 3G-SDI.

2.3.3.16.3   2 x DVI-D (with 1 x optical adapter).

2.3.3.16.4   1 x YUV.

2.3.3.16.5   1 x Y/C (only SD format).

2.3.3.16.6   1 x FBAS (only SD format).

2.3.3.16.7   1 x RJ45.

2.3.3.17   Flexible Data Storage:

2.3.3.17.1   Images may be saved to USB memory devices during procedures.

** NOTE TO SPECIFIER ** Delete if not required. Delete features not required.

2.4   MONITOR HOLDERS

2.4.1   Basis of Design: Hill-Rom Architectural Products, Trumpf Medical; Monitor Support System.

** NOTE TO SPECIFIER ** Note that monitors are sold separately.

2.4.1.1   Monitor Support Arm Holders: Spring arms and holders.

2.4.1.1.1   Support arm and bracket for 26 inch (660 mm) solo.