Analysis Report for Above Activity Is Compulsory For

Analysis Report for Above Activity Is Compulsory For

1: Assembling of Diesel Engines

Effluent :

S. No. / Parameters / Standards / Unit
Min Value / Max Value
Dry Unit / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Insignificantly Polluting / - / - / -

Hazardous Nature of this activity: Yes

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:No

iii)Renewal:No

2: Automobile and Coach Building (Small Scale)

Effluent :

S. No. / Parameters / Standards / Unit
Min Value / Max Value
Dry Unit / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Insignificantly Polluting / - / - / -

Hazardous Nature of this activity: Yes

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:No

iii)Renewal:No

3: Automobile Repair & Servicing (Without Washing)

Effluent :

S. No. / Parameters / Standards / Unit
Min Value / Max Value
Dry Unit / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Insignificantly Polluting / - / - / -

Hazardous Nature of this activity: Yes

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:No

iii)Renewal:No

4: Aerated Water And Fruit Beverage

Effluent :

S. No. / Parameters / Standards / Unit
Min Value / Max Value
i) / pH / 6.5 / 8.5
ii) / TSS / 0 / 100 / mg/l
iii) / BOD / 0 / 30 / mg/l
iv) / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter (in case of Boiler) / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used / spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:Yes

iii)Renewal:Yes

5: Aluminum Casting (By Pit Furnace Only), Rolling (with capacity less than 25 MT/day) And Annealing

Effluent :.

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / No Effluent Report is required since no effluent is discharged / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matters* / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level , whichever is higher.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:Yes

iii)Renewal:Yes

6: Aluminium Pressure Die Casting

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / No Effluent Report is required / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matters* / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level , whichever is higher.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

iv)Establish:No

v)Operate:Yes

vi)Renewal:Yes

7: Ancillary Units of Slaughter House

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / TSS / 0 / 50 / mg/l
2 / BOD / 0 / 30 / mg/l
3 / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter (in case of Boiler/ Furnace) / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level , whichever is higher.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

vii)Establish:No

viii)Operate:Yes

ix)Renewal:Yes

8: Anodising: Omitted and updatedat other S.No.
9: Asbestos Based Products

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Asbestos / 0 / 0.2 Fibres* /cc

* Fibre of length more than 5 micrometer and diameter less then 3 micrometer with an aspect ratio of 3 or more.

*Minimum stack height shall be2 mts above roof level .

Hazardous Nature of this activity:Yes

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:Yes

iii)Renewal:Yes

10: Automobile Fuel Outlet (With Automobile Servicing, Repairing And Painting)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9.0
2 / TSS / 0 / 250 / mg/l
3 / BOD / 0 / 150 / mg/l
4 / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Channelization of emissions / - / - / -

Hazardous Nature of this activity:Yes

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:Yes

iii)Renewal:Yes

11: Automobile Servicing And Repair Station With Washing Activity

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9.0
2 / TSS / 0 / 250 / mg/l
3 / BOD / 0 / 150 / mg/l
4 / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Channelization of emissions / - / - / -

Hazardous Nature of this activity:Yes

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:Yes

iii)Renewal:Yes

12: Bakelite Powder Mfg. Using Phenol Formaldehyde Resin As Raw Material And Bakelite Products

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:Yes

iii)Renewal:Yes

13: Bakery Products and Confectionery with Trade Effluent/Emission Discharge

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 6.5 / 8.5
2 / TSS / 0 / 50 / mg/l
3 / BOD / 0 / 30 / mg/l
4 / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter (in case of Boiler/ oil fired Furnace) / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

14:Banquet Hall/Party Lawn(Minimum Area 100 SqMts) : Omitted and updated at other S.No.

15: Batteries (Lead Acid) And Accessories

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 6.5 / 8.5
2 / Suspended Solid / 0 / 50 / mg/l
3 / Lead / 0 / 0.1 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Lead / 0 / 10 / mg/Nm³
2. / Particulate Matter* / 0 / 25 / mg/Nm³

*Minimum stack height shall be 30 mts above ground level.

Hazardous Nature of this activity:No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

16: Battery Containers (PVC Section)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matters / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity:No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

17: Buffing On Metal

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matters / 0 / 150 / mg/Nm³

*Minimum stack height shall be2 mts above roof level.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

18: Bulk Cement Terminal (Storage) (100 Tonne& Above)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matters / 0 / 150 / mg/Nm³

*Minimum stack height shall be2 mts above roof level.

Hazardous Nature of this activity:No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

19: C.I. Malleable Pipe Fittings (With Casting Only With Pit Furnace)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

20: Cardboard/ Paper or Corrugated Box & Other Products (With Printing Activity Including Effluent Generation) from Card board as raw material

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9
2 / Suspended Solids (SS) / 0 / 250 / mg/l
3 / BOD / 0 / 150 / mg/l
4 / Oil & Grease / 0 / 10 / mg/l
5 / Bio-assay test / 90% survival of fish after 96 hours
6 / Total Chromium (as Cr) / 0 / 2 / mg/l
7 / Sulphide (as S) / 0 / 2 / mg/l
8 / Phenolic compounds (as C4H2OH) / 0 / 5 / mg/l
9 / Zinc / 0 / 5 / mg/l
10 / Total Metal / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Channelization of emissions / - / - / -

Hazardous Nature of this activity:Yes

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

21: Cashewnut Processing Plants (Dry Process)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter (in case of oil fired Furnace) / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

22: Casting of Ferrous/ Non Ferrous Metal (By Using Pit Furnace Only)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

23: Cattle Feed

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity:No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

24: Cement Clinker Grinding Units

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity:No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

25: Cement Paint Powder and Distemper

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be2 mts above roof level.

Hazardous Nature of this activity:Yes

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

26: Cement Tiles Using Fly Ash (With Trade Effluent Discharge)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9.0
2 / TSS / 0 / 250 / mg/l
3 / BOD / 0 / 150 / mg/l
4 / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be2 mts above roof level.

Hazardous Nature of this activity:No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for s

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

27: Cement products (Small Scale)

Effluent :

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9.0
2 / TSS / 0 / 250 / mg/l
3 / BOD / 0 / 150 / mg/l
4 / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / PM / 0 / 150 / mg/Nm³

*Minimum stack height shall be2 mts above roof level.

Hazardous Nature of this activity: No (used / spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:Yes

iii)Renewal:Yes

28: Cement Tiles Using Fly Ash (Without Trade Effluent Discharge)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be2 mts above roof level.

Hazardous Nature of this activity:No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

29: Chilly Powder (Grinding Activity)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be2 mts above roof level.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

30: Chilling Plants and Cold Storages (Integrated) (Excluding meat/ food processing)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9.0
2 / TSS / 0 / 250 / mg/l
3 / BOD / 0 / 150 / mg/l
4 / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Insignificantly Polluting / - / - / -

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

31: Coated Cotton Fabrics (PVC Rexene Cloth)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

32: Cold re Rolling without Pickling of S .S. Sheets (with capacity less than 25 MT/ day)

Effluent:.

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Insignificantly Polluting / - / - / -

Hazardous Nature of this activity:No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:No
  • Renewal:No
    33:Colour/Black & White Photo studio With Film Development Process

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9.0
2 / Total Standards of mercury(Hg.)in the final
(Combined) effluent / 0 / 0.01 / mg/l
3 / Suspended Solids / 0 / 250 / mg/l
4 / Biochemical Oxygen Demand / 0 / 150 / mg/l
5 / Oil & Grease / 0 / 10 / mg/l
6 / Phosphate (as P) / 0 / 5.0 / mg/l
7 / Sulphide (as S) / 0 / 2 / mg/l
8 / Phenolic Compounds (as C6H5OH) / 0 / 5 / mg/l
9 / Ammomtacal Nitrogen ( as N) / 0 / 50 / mg/l
10 / Total Metal / 0 / 10.0 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / channelization of emissions / - / - / -

Hazardous Nature of this activity:No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

34: Conduit Pipes (Plastic) using fresh raw material

Effluent : s

S. No. / Parameters / Standards / Unit
Min Value / Max Value
Dry unit / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / PM / 0 / 150 / mg/Nm³
2 / HCL mist &vapour / 0 / 35 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used / spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:No

iii)Renewal:No

35: Conduit Pipes (Plastic) using plastic scrap without trade effluent discharge.

Effluent :

S. No. / Parameters / Standards / Unit
Min Value / Max Value
Dry unit / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / PM / 0 / 150 / mg/Nm³
2 / HCL mist &vapour / 0 / 35 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used / spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:No

iii)Renewal:No

36: Conduit Pipes (Plastic) using plastic scrap with trade effluent discharge.

Effluent :

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9
2 / TSS / 0 / 250 / mg/l
3 / BOD / 0 / 150 / mg/l
4 / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / PM / 0 / 150 / mg/Nm³
2 / HCL mist &vapour / 0 / 35 / mg/Nm³

*Minimum stack height shall be 11 mts above ground level or 2 mts above roof level, whichever is higher.

Hazardous Nature of this activity: No (used / spent oil if any will be sent to registered recycler only)

Analysis report for above activity is compulsory for

i)Establish:No

ii)Operate:No

iii)Renewal:No

37: Concreteand Mosaic Products (Without Trade Effluent Discharge)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Dry / - / - / -

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be2 mts above roof level.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

38: Concrete and Mosaic Products (With Trade Effluent Discharge)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9
2 / TSS / 0 / 250 / mg/l
3 / BOD / 0 / 150 / mg/l
4 / O&G / 0 / 10 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / Particulate Matter / 0 / 150 / mg/Nm³

*Minimum stack height shall be2 mts above roof level.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

39: Contact Lens (With Trade Effluent)

Effluent:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / pH / 5.5 / 9.0
2 / TSS / 0 / 250 / mg/l
3 / O&G / 0 / 10 / mg/l
4 / Phosphate (as P) / 0 / 5 / mg/l

Emission:

S. No. / Parameters / Standards / Unit
Min Value / Max Value
1 / PM / 0 / 150 / mg/Nm3

*Minimum stack height shall be 2 mts above roof level.

Hazardous Nature of this activity: No (used/ spent oil if any will be sent to registered

recycler only)

Analysis report for above activity is compulsory for

  • Establish:No
  • Operate:Yes
  • Renewal:Yes

40: Contact Lens (Without Trade Effluent)