Number of Pages in This Package ____

Number of Pages in This Package ____

Project No. / 2259022 / File / Page / 1
LABORATORY DATA PACKAGE / Date

Number of pages in this package ____

TEST LOCATION:
[x]UL or Affiliate / []WTDP / []CTDP / []OTHER
Company Name
Address
CLIENT INFORMATION
Company Name / ONE LAPTOP PER CHILD
Address /
AUDIT INFORMATION:
[ ] Description of Tests / Specialized Condensation testing as requested by client / Edition
[X] Tests Conducted by + / Joe Vanis / Joe Vanis
Printed name / Signature
[] UL Staff witnessing testing (WTDP only)
Printed name / Signature
Reviewed and accepted by qualified Project Handler / Joseph Allen /
Printed Name / Signature
TESTS TO BE CONDUCTED:
Test No. / Start / Done / Test Name / [] Comments/Parameters
[]Tests Conducted by ++
1 / 10/11/07 / 10/23/07 / Cold Storage Test / Samples 1,2,3,4,5

Test Equipment- See "TEST EQUIPMENT INFORMATION"

Samples – See "TEST SAMPLE IDENTIFICATION"

Instructions -

+ - When all tests are conducted by one person, printed name and signature can be inserted here instead of including printed name and signature on each page containing data. Must indicate number of pages in the data package.

++ - When test conducted by more than one person, printed name and signature of person conducting the test can be inserted next to the test name instead of including printed name and signature on each page containing data. Must indicate number of pages in the data package.

Special Instructions -

ULS-00923-KQSQ-Datasheet-2001 / Form Issued: / 2004-05-03
Form Page 1 / Form Revised: / 2004-09-22
Form Copyright  2004 Underwriters Laboratories Inc.

Only those products bearing the UL Mark should be considered as being covered by UL.

Project No. / 2259022 / File / Page / 1
Tested by: / Date
Printed Name / Signature

TEST EQUIPMENT INFORMATION

See Meter Usage Tool Database.

Inst. ID No. / Instrument Type / Test Number +, Test Title or Conditioning / Function/Range / Last Cal. Date / Next Cal. Date
NBK25774 / Timer - Digital / ONE LAP TOP PER CHILD COLD STORAGE TEST / 24 HR. / 09/07/2007 / 09/30/2008
TCR3042 / Temperature Recorder / ONE LAP TOP PER CHILD COLD STORAGE TEST / 0-100 DEG C 0-100 % RH / 04/19/2007 / 04/30/2008
usnbk00675 / Temperature Indicator - Digital / ONE LAP TOP PER CHILD COLD STORAGE TEST / -200 to 1200 C, -200 to 2192 F / 03/07/2007 / 03/31/2008

+ - If Test Number is used, the Test Number must be identified on the data sheet pages or on the Data Sheet Package cover page.

[X]Test equipment information is recorded on UL’s Laboratory Project Management (LPM)/Laboratory Equipment Management (LEM) database. (This statement may be selected only if datasheets are completed electronically at a UL facility)

TEST SAMPLE IDENTIFICATION:

The table below is provided to provide correlation of sample numbers to specific product related information. Refer to this table when a test identifies a test sample by "Sample No." only.

Sample Card No. / Date Received / [x] Test No. / Sample No. / Manufacturer, Product Identification and Ratings
964711 / 9/28/07 / ONE LAPTOP PER CHILD, 5 laptops, 5 power supplies, 5 batteries

+ - If Test Number is used, the Test Number or Numbers the sample was used in must be identified on the data sheet pages or on the Data Sheet Package cover page.

[] Sampling Procedure -

ONE LAP TOP PER CHILD COLD STORAGE TEST:

METHOD

Each of 5 laptops is subjected to 6 trials of extreme cold storage temperature. The first three trials repeatedly subject the laptop to -25C for 24 hours, then the laptops are moved into 25C at 85%RH for one hour before booting up (turning the laptop on). A successful boot up indicates the laptop has passed. The second three trials decrease the storage temperature to -50C for 24 hours at a time, then again the laptops are moved into 25C at 85%RH for one hour before booting up (turning the laptop on). Each of 5 laptops is subjected to 6 cycles of intense cooling followed by warming to room temperature. The results are shown above.

Via client and project handler temperature and humidity was changed to 32C and 88%.

Samples were charged prior to testing.

ULS-00923-KQSQ-Datasheet-2001 / Form Issued: / 2004-05-03
Form Page 1 / Form Revised: / 2004-09-22
Form Copyright  2004 Underwriters Laboratories Inc.

Only those products bearing the UL Mark should be considered as being covered by UL.

Project No. / 2259022 / File / Page / 1
Tested by: / Date
Printed Name / Signature

RESULTS

Laptop 1 / Laptop 2 / Laptop 3 / Laptop 4 / Laptop 5
Serial Number / SHF70600420 / SHF706003C7 / SHF7050009E / SHF706001C2 / SHF7060039E
Trial 1
(-)25C for 24 hours / Start: 10/11/07
5:10AM -25.2C / Start: 10/11/07
5:10AM -25.2C / Start: 10/11/07
5:10AM -25.2C / Start: 10/11/07
5:10AM -25.2C / Start: 10/11/07
5:10AM -25.2C
25C 85%
32C and 88%RH for 1 hour / Start: 10/12/07
5:10AM 32.2C
88.5% / Start: 10/12/07
5:10AM 32.2C
88.5% / Start: 10/12/07
5:10AM 32.2C
88.5% / Start: 10/12/07
5:10AM 32.2C
88.5% / Start: 10/12/07
5:10AM 32.2C
88.5%
Turn on Laptop (bootup) / Start: 10/12/07
6:10AM / Start: 10/12/07
6:10AM / Start: 10/12/07
6:10AM / Start: 10/12/07
6:10AM / Start: 10/12/07
6:10AM
Boots up to sugar screen / 10/12/07 - Pass / 10/12/07 - Pass / 10/12/07 - Pass / 10/12/07 - Pass / 10/12/07 - Pass
Trial 2
(-)25C for 24 hours / Start: 10/15/07
3:45AM -25.2C / Start: 10/15/07
3:45AM -25.2C / Start: 10/15/07
3:45AM -25.2C / Start: 10/15/07
3:45AM -25.2C / Start: 10/15/07
3:45AM -25.2C
25C 85%
32C and 88%RH for 1 hour25C 85%RH for 1 hour / Start: 10/16/07
3:45AM 31.9C
88.1% / Start: 10/16/07
3:45AM 31.9C
88.1% / Start: 10/16/07
3:45AM 31.9C
88.1% / Start: 10/16/07
3:45AM 31.9C
88.1% / Start: 10/16/07
3:45AM 31.9C
88.1%
Turn on Laptop (bootup) / Start: 10/16/07
4:45AM / Start: 10/16/07
4:45AM / Start: 10/16/07
4:45AM / Start: 10/16/07
4:45AM / Start: 10/16/07
4:45AM
Boots up to sugar screen / 10/16/07 - Pass / 10/16/07 - Pass / 10/16/07 - Pass / 10/16/07 - Pass / 10/16/07 - Pass
Trial 3
(-)25C for 24 hours / Start: 10/16/07
5AM -27.3C / Start: 10/16/07
5AM -27.3C / Start: 10/16/07
5AM -27.3C / Start: 10/16/07
5AM -27.3C / Start: 10/16/07
5AM -27.3C
25C 85%
32C and 88%RH for 1 hour25C 85%RH for 1 hour / Start: 10/17/07
5AM 31.8C
88.1% / Start: 10/17/07
5AM 31.8C
88.1% / Start: 10/17/07
5AM 31.8C
88.1% / Start: 10/17/07
5AM 31.8C
88.1% / Start: 10/17/07
5AM 31.8C
88.1%
Turn on Laptop (bootup) / Start: 10/17/07
6AM / Start: 10/17/07
6AM / Start: 10/17/07
6AM / Start: 10/17/07
6AM / Start: 10/17/07
6AM
Boots up to sugar screen / 10/17/07 - Pass / 10/17/07 - Pass / 10/17/07 - Pass / 10/17/07 - Pass / 10/17/07 - Pass
Trial 4
(-)50C for 24 hours / Start: 10/17/07
7AM –49.8C / Start: 10/17/07
7AM –49.8C / Start: 10/17/07
7AM –49.8C / Start: 10/17/07
7AM –49.8C / Start: 10/17/07
7AM –49.8C
25C 85%
32C and 88%RH for 1 hour25C 85%RH for 1 hour / Start: 10/18/07
7:15AM 31.9C
88.1% / Start: 10/18/07
7:15AM 31.9C
88.1% / Start: 10/18/07
7:15AM 31.9C
88.1% / Start: 10/18/07
7:15AM 31.9C
88.1% / Start: 10/18/07
7:15AM 31.9C
88.1%
Turn on Laptop (bootup) / Start: 10/18/07
8:15AM / Start: 10/18/07
8:15AM / Start: 10/18/07
8:15AM / Start: 10/18/07
8:15AM / Start: 10/18/07
8:15AM
Boots up to sugar screen / 10/18/07 – Pass* / 10/18/07 - Pass / 10/18/07 - Pass / 10/18/07 – Pass* / 10/18/07 – Pass*
Trial 5
(-)50C for 24 hours / Start: 10/18/07
8:30AM -49.8C / Start: 10/18/07
8:30AM -49.8C / Start: 10/18/07
8:30AM -49.8C / Start: 10/18/07
8:30AM -49.8C / Start: 10/18/07
8:30AM -49.8C
25C 85%
32C and 88%RH for 1 hour25C 85%RH for 1 hour / Start: 10/19/07
8:30AM 31.9%
87.8% / Start: 10/19/07
8:30AM 31.9%
87.8% / Start: 10/19/07
8:30AM 31.9%
87.8% / Start: 10/19/07
8:30AM 31.9%
87.8% / Start: 10/19/07
8:30AM 31.9%
87.8%
Turn on Laptop (bootup) / Start: 10/19/07
9:30AM / Start: 10/19/07
9:30AM / Start: 10/19/07
9:30AM / Start: 10/19/07
9:30AM / Start: 10/19/07
9:30AM
Boots up to sugar screen / 10/19/07* / 10/19/07 - Pass / 10/19/07 - Pass / 10/19/07* / 10/19/07*
Trial 6
(-)50C for 24 hours / Start: 10/22/07
4AM -48.9C / Start: 10/22/07
4AM -48.9C / Start: 10/22/07
4AM -48.9C / Start: 10/22/07
4AM -48.9C / Start: 10/22/07
4AM -48.9C
25C 85%
32C and 88%RH for 1 hour25C 85%RH for 1 hour / Start: 10/23/07
4AM 31.9%
87.9% / Start: 10/23/07
4AM 31.9%
87.9% / Start: 10/23/07
4AM 31.9%
87.9% / Start: 10/23/07
4AM 31.9%
87.9% / Start: 10/23/07
4AM 31.9%
87.9%
Turn on Laptop (bootup) / Start: 10/23/07
5AM / Start: 10/23/07
5AM / Start: 10/23/07
5AM / Start: 10/23/07
5AM / Start: 10/23/07
5AM
Boots up to sugar screen / 10/23/07* / 10/23/07 - Pass / 10/23/07 - Pass / 10/23/07* / 10/23/07*
ULS-00923-KQSQ-Datasheet-2001 / Form Issued: / 2004-05-03
Form Page 1 / Form Revised: / 2004-09-22
Form Copyright  2004 Underwriters Laboratories Inc.

Only those products bearing the UL Mark should be considered as being covered by UL.

Project No. / «ProjectNumber» / File / «FileNumber» / Page / 1
Tested by: / Date
Printed Name / Signature

* = Sample 1, SHF70600420, Sample 4, SHF706001C2 and Sample 5, SHF7060039E, operated as they had before with one exception. After the fourth cycle all three of the samples' displays had a dimmed appearance. The displays were still readable but were not clean and clear.

After the fifth cycle finished Sample 1, SHF70600420, the display did not operate at all. The Power LED lit up and was green proving the sample was ON, yet the display was completely dead, no activity. Sample 4,SHF706001C2 and Sample 5, SHF7060039E, the displays lit up to a white screen and did nothing else. The Power LED and the two LEDs on the bottom left of the display lit up on both samples proving that both samples were ON and running, yet the displays remained white.

After the sixth cycle finished Sample 1, SHF70600420, the display did not operate at all. The Power LED lit up and was green proving the sample was ON, yet the display was completely dead, no activity. Sample 4,SHF706001C2 and Sample 5, SHF7060039E, the displays lit up to a white screen and did nothing else. The Power LED and the two LEDs on the bottom left of the display lit up on both samples proving that both samples were ON and running, yet the displays remained white.

END OF DATASHEET PACKAGE. THIS PAGE INTENTIONALLY LEFT BLANK