Green and Fast Synthesis of Amino Functionalized Graphene Quantum Dots with Deep Blue

Green and Fast Synthesis of Amino Functionalized Graphene Quantum Dots with Deep Blue

Green and fast synthesis of amino functionalized graphene quantum dots with deep blue photoluminescence

E. Blanco[1], G. Blanco, J.M. Gonzalez-Leal, M.C. Barrera, M. Domínguez, M. Ramirez-del-Solar

Institute of Electron Microscopy and Materials.University of Cádiz

Campus Universitario de Puerto Real. 11510- Puerto Real (Cádiz) (SPAIN)

SUPPLEMENTARY MATERIAL

-Photoluminescence study of H_0, H_1300 and H_1900 samples, referred but not shown in the paper.

-Raman map and hystogram for the relation of intensities of D and G bands, ID/IG, for the samples covering an area o of 5 μm × 5 μm.

-AFM image

Fig. S1PL emission spectra of diluted H_0 sample recorded at increasing excitation wavelengths from 310 to 500nm (up). PL excitation spectrum of the same sample with the detection wavelength of 413 nm (down).

Fig. S2Up-conversion PL emission (up) and excitation (down) spectra of sample H_0. Emission spectra were recorded for excitation wavelengths ranging from 560-800nm.

Fig. S3PL emission spectra of diluted H_1300 sample recorded at increasing excitation wavelengths from 310 to 500nm (up). PL excitation spectrum of the same sample with the detection wavelength of 410 nm (down)

Fig. S4Up-conversion PL emission (up) and excitation (down) spectra of sample H_1300. Emission spectra were recorded for excitation wavelengths ranging from 560-800nm.

Fig. S5PL emission spectra of diluted H_1900 sample recorded at increasing excitation wavelengths from 310 to 500nm (up). PL excitation spectrum of the same sample with the detection wavelength of 412 nm (down)

Fig. S6Up-conversion PL emission (up) and excitation (down) spectra of sample H_1900. Emission spectra were recorded for excitation wavelengths ranging from 560-800nm

Fig. S7 As an example, Raman maps (up) of H_0, H_1300, H_1900 and H_3200 samples for the ID/IG relation (area/area). The corresponding histograms (down) have been used to obtain the averaged values shown in Table 2 in the text. Similar procedure has been followed for the other parameters in Table 2.

Fig. S8 Up, AFM topography image of the GQDs deposited onto a freshly-cleaved mica plate. The false-colour height scale is shown on the right. Down,height profiles taken along the lines 1-3 drawn in the image.This is the second image of the study referred in the article.

Electronic Supplementary materials

Supporting information includes photoluminescence study of H_0, H_1300, and H_1900 samples, referred but not shown in the paper, figures S1 to S6. Raman map and histogram for the relation of intensities of D and G bands, ID/IG, for the samples covering an area o of 5μm×5μm, figure S7. AFM topography image of the GQDs and height profiles, figure S8. This is the second image of the study referred in the article.

[1]Corresponding autor: . Phone: 34-956016326 Fax:34-956016288