10517 version 4
Page 1 of 4
Overhaul electricity network tower foundations
Level / 4Credits / 8
PurposePeople credited with this unit standard are able to: plan work and establish a site for the overhaul of electricity network tower foundations; excavate and expose electricity network foundations; remove condemned foundation elements; reinstate the structural integrity of tower foundations; place tower foundation concrete; reinstate tower foundation work site; and report on the overhaul of electricity network tower foundations.
Subfield / Electricity SupplyDomain / Electricity Supply-Transmission Networks
Status / Registered
Status date / 11 December 2009
Date version published / 11 December 2009
Planned review date / 31 December 2014
Entry information / Prerequisites: Unit 10507, Use personal protection equipment within an electricity network environment; and Unit 18022, Repair electricity network tower footings; or demonstrate equivalent knowledge and skills.
Accreditation / Evaluation of documentation and visit by NZQA and industry.
Standard setting body (SSB) / Electricity Supply Industry Training Organisation
Accreditation and Moderation Action Plan (AMAP) reference / 0120
This AMAP can be accessed at
Special notes
1This unit standard is intended for, but not restricted to, workplace assessment. The range statements across the unit standard can be applied according to industry specific equipment, procedures, and processes.
2Safety of personnel and plant must be a priority throughout the assessment. If the safety requirements are not met the assessment must stop.
3Performance and work practices in relation to the elements and performance criteria must comply with all current legislation, especially the Electricity Act 1992, and any regulations and codes of practice recognised under that statute; the Health and Safety in Employment Act 1992; and the Resource Management Act 1991. Electricity supply industry codes of practice and documented industry procedures include the Safety Manual – Electricity Industry (SM-EI) (2004) Wellington: Electricity Engineers’ Association. A full list of current legislation and industry codes is available from the Electricity Supply Industry Training Organisation, PO Box 1245, Waikato Mail Centre, Hamilton 3240.
4The phrase in accordance with industry requirements is implicit in all elements and performance criteria in this unit standard.
5Industry requirementsinclude all asset owner requirements; manufacturers’ specifications; and enterprise requirements which cover the documented workplace policies, procedures, specifications, and business and quality management requirements relevant to the workplace in which assessment is carried out.
Elements and performance criteria
Element 1
Plan work and establish a site for the overhaul of electricity network tower foundations.
Performance criteria
1.1Work scope is identified.
1.2Site is prepared.
Element 2
Excavate and expose electricity network foundations.
Performance criteria
2.1Tower is supported and guyed.
2.2Tower foundation is exposed.
Element 3
Remove condemned electricity network foundation elements.
Performance criteria
3.1Tower leg is removed.
3.2Condemned foundation elements are removed.
Rangebolts, concrete, steel, stubs.
Element 4
Reinstate the structural integrity of electricity network tower foundations.
Performance criteria
4.1Formwork is determined and positioned.
Rangemoulds, settings jigs, templates.
4.2Reinforcing is installed.
4.3Tower holding components are assembled.
Rangebolt cages, stubs.
4.4Tower holding components are placed.
4.5Tower leg is reinstalled.
Element 5
Place tower foundation concrete.
Performance criteria
5.1Concrete is placed.
Rangedirect from barrel drum mixer, pump, hopper-crane, helicopter.
5.2Concrete samples are taken and proven.
5.3Concrete is finished.
Element 6
Reinstate tower foundation work site.
Performance criteria
6.1Formwork and debris are removed.
6.2Site is reinstated.
Element 7
Report on the overhaul of electricity network tower foundations.
Performance criteria
7.1Work is reported and recorded as built.
7.2Existing records are updated.
Please note
Providers must be accredited by NZQA, or an inter-institutional body with delegated authority for quality assurance, before they can report credits from assessment against unit standards or deliver courses of study leading to that assessment.
Industry Training Organisations must be accredited by NZQA before they can register credits from assessment against unit standards.
Accredited providers and Industry Training Organisations assessing against unit standards must engage with the moderation system that applies to those standards.
Accreditation requirements and an outline of the moderation system that applies to this standard are outlined in the Accreditation and Moderation Action Plan (AMAP). The AMAP also includes useful information about special requirements for organisations wishing to develop education and training programmes, such as minimum qualifications for tutors and assessors, and special resource requirements.
Comments on this unit standard
Please contact the Electricity Supply Industry Training you wish to suggest changes to the content of this unit standard.
New Zealand Qualifications Authority 2018