TARGET CORPORATION

FEBRUARY 2005

Elevator QEI / Performance Report

FREIGHT ELEVATOR #3

T-1054 TARGET

TANFORAN PARK

1150 EL CAMINO REAL

SAN BRUNO, CA 94066

by: Elevator Consulting Services, Inc.

FREIGHT ELEVATOR

Equipment Inventory -- Main Machine Room

Control Type: SAPB

Contract Speed: 65 FPM- UP

70 FPM – DN

Machine Type: MINNESOTA PUMP UNIT

VIRGINIA CONTROLLER

Door Equipment: COURION

Door Size/Type: 12’ 0’ WIDE X 8’ 0” HIGH

Number of Openings: THREE (3) IN LINE

Travel: 35’ 0”

Floors Served: *1, 2, 3

Complex Unit No.: 5

City / State Number: 11035

Capacity: 8000 LBS

Emergency Light: OK

Alarm Bell: OK

Maintenance Log: SIGN IN AT GUEST SERVICES


PERFORMANCE

Speed Up: 95 FPM

Speed Down: 95 FPM

Perform Up: 18.9 SEC

Perform Down: 19.2 SEC

Door Open: 7.5 SEC

Door Close: 7.5 SEC

ALL +/- .2 SEC

Ride Quality

Ride: OK

Deceleration Up: OK

Deceleration Down: OK

Acceleration Up: OK

Acceleration Down: OK

Stop: OK

Leveling: OK


Equipment Room

Access: OK

Headroom: OK

Enclosure: OK

Lighting: OK

OLD STYLE FLORESCENT – UPGRADE TO T8

Cleanliness: OK

Air Circulation,Ventilation: OK

Pipes, Ducts, Non Elev: NONE

Parts: OK

GFIC Receptacle : REG UNIT

Fire Extinguisher: OK

SERVICED 10-04

Guarding: OK

Self Closing, Locking door: OK

VENTED THROUGH DOOR

Numbering of Units: NI

Smoke Head: YES

Sprinkler in Room: YES

Heat Head: NO

Lockable, fused disconnect: YES

BREAKER

110 Volt Disconnect: YES

Shunt Trip Protection: NO

MSDS documentation: OK

Oil Monitoring Sheet: OK

Signage on door: OK – “EQUIPMENT ROOM” ONLY

Control Panel

Type of Control: RELAY MH

Manufacturer: VIRGINIA

Install Date: 1997

Installation Code: TITLE 8 GROUP II

ASME 17.1 1996

Cleanliness: OK

Identification: OK

JOB # MHF 1216

Software Version: GE FANUC

SERIES 90-30

Guarding: OK

U. L. Label: OK

Components-Controller

Relays: OK

Enclosed / Open Style: ENCLOSED

Contacts: OK

Capacitors: OK

Resistors: OK

P.C. Boards / Timer: NI

Wiring: OK

Performance: OK

Rectifiers: N/A

Door Controller

Mfg: COURION

Model: E

Relays: OK

Resistors: OK

Capacitors: OK

Coils: OK

Motherboard: OK

Fuses: OK

Timers: OK

Starters

Type: WYE DELTA

Mfg: TELEMANIQUE

Size: D40

Contacts: OK

Connections: OK

Rescuvator

Mfg: REYNOLDS & REYNOLDS

Model: UV3-480 / 220

Serial No.: 960-0651-1

Meters: OK

Wiring: OK

Battery: OK

Pump Unit

Mfg: MEI

Model: MHF 1216

Cleanliness: OK

Leaks: NONE

Noise: OK

Oil Level: OK

Oil: OK

Belts: N/A

Sheaves: N/A

Pump: OK – IMO 250

Subs/ Dry: SUBS

Shut Off: NO

Valves: OK

UC-2A

Muffler: IN-LINE

Seals: OK

Covers: OK

Viscosity Control: N/A

Acceptance Test: OK

Tagged: 11-8-96

Load Test: OK

Tagged: 2-04

MITSUBISHI

Oil Coolers

Existing: YES

Model: DAD

Fins: OK

Fans: OK

Wiring: OK

Motor

Isolation: OK

Grounded: OK

Covers: OK

HP: 50

RPM: 1750

AMPS: 118 / 59

Starts / Hr: 80


Hoistway Equipment

Selector Car Top Device

Cleanliness: OK

Tape: OK

Tape Guides: OK

Wiring: OK

Limit Switches

Roller Noise: OK

Operation: OK

Type: GEM / MEI STND

Rails

Cleanliness: OK

Lubrication: OK

Type: T / JUMBO – 22 LBS

Fastening: OK

Shoes: OK

Cable Condition

Traveling: OK

TC Suspension: OK

Piston Traveler: N/A

TC Spares: OK

Hoist Cables: N/A

Cable Ties: N/A

Shackles: N/A

Hoistway Equipment

Car Top

Cleanliness: FAIR

Maintenance Station: OK

Stop Switch: OK

Data Plate: YES

Light: OK

Light guards: OK

Guides: OK

GFIC Receptacles: NO

Emerg exit locked: YES

Windows in Hoistway: N/A

Multiple Hoistways: N/A

Stenciled: NO

Hoistway Venting

Existing: NONE

Motorized: N/A

Safety Bars: N/A

Key Switch: N/A

Size (3%): N/A

Gate Operator - Courion

Cleanliness: OK

Door Protection: SAFETY EDGES

TAPE BOOT

Lubrication: OK

Belts: OK

Chains: MONITOR

Limit Assembly: OK

Idler Sheaves: OK

Sprockets: OK

Noise OK

Tracks: OK

Shoes: OK

Car Enclosure

Ventilation: OK

OPEN

Walls: STEEL W / ALUMINUM DECKING WAINSCOT

Car Lighting: FLORESCENT

OLD STYLE FIXTURES

Ceiling: STEEL

Position Indicators: NONE

Handrails / Bumpers: 2 STAINLESS RAILS / 3 WALLS

AT 15 & 35 “ TO TOP

Flooring: STEEL DECKING

Gate: MESH

Certificate: NO / FRAME EXISTS


Entrance Equipment

Cleanliness: FAIR

Lubrication: OK

Tracks: OK

Chains: OK

Shoes: OK

Interlocks: QIP / COURION

Noise: OK

Covers: OK

Motors: OK

Belts: OK

Access Devices: OK

Emergency Fire Box

Main Egress Landing: 1

Existing in Lobby: NO

Machine Room Key: NO

Phase I, II Keys: NO

Pit Access Key: NO

Tagged: NO

Car Operating Panel

Type: ADAMS VANDAL RESISTANT

Height Compliance: OK

Braille Identification: YES

Buttons: OK

Phone: PUSH TO TALK

Alarm Button: OK

Stop Switch: PUSH / PULL

Emergency Light: NO

Capacity Plate / Engraved: OK

Fire Fighters Inst: NO

Phase II Key Switch: YES

OFF / ON

Certificated: FRAME ONLY

Signage: OK

C1 LOADING

Hall Buttons

Type: ADAMS VANDAL RESISTANT

Illuminated: YES

Height: OK

Mechanical: YES

Lanterns: NO

Fire Signage: ENGRAVED IN FACE PLATE

Phase I Key Switch: YES

Phase I Instructions: YES


Pit Equipment

Cleanliness: FAIR

Car Buffer: OK

Cwt Buffer: N/A

Lights: OK

Light Guards: OK

Light Switch: OK

Stop Switch: OK

Ladder: OK

GFIC Receptacles: YES

Rupture Valve: YES

Jack seal: OK

PVC Liner: NO

Shut Off: YES

Piston pans: N/A


Bottom of Car

Cleanliness: OK

Safeties: N/A

Trav Cable Suspension: OK

Toe Guard Length: NON CONFORMING / 9” TO BEND

CODE IS 21”

Isolation: NONE

Light Fixture: OK

Light Guard: OK

Guides: OK

Receptacle: PORCELAIN FIXTURE ONLY

GFI Receptacle: NO

T-1054 TARGET

SAN BRUNO, CA

FREIGHT ELEVATOR

CORRECTIVE ITEMS

The following minimum items need corrective action taken. Documentation on completion is required.

Load Test – 2-04

1.   Replace the pit light bulb.

2.   Vacuum the car top.

3.   Label RED relay or replace with adjustable resistor.

4.   Controller takes 2 to 3 minutes to recycle if main line is turned off before rescuvator. Investigate why.

T-1054 TARGET

FREIGHT ELEVATOR

SAN BRUNO, CA

RECOMMENDED IMPROVEMENTS

1.  The jack was never capped at the pit floor. This leaves it open for debris to fall down the hole and create potential problems. Cap the jack hole with concrete, mesh system.
Budget $ 2,400.00

2.  Install “Elevator Equipment Room” signage on the machine room door. Budget $ 90.00

3.  Provide adequate machine room lighting. Light shall provide a minimum of 10 foot candles at the floor level. ASME 17.3 Rule 2.2.3

4.  Provide compliant cab lighting. There shall be not less than two lamps and provide a minimum of 5 ftc for passenger elevators and 2.5 ftc for freight elevators. ASME 17.3 Rule 3.4.5,

5.  Install heat heads per contract.

6.  Upgrade the existing receptacles to a GFIC receptacle in the pit and machine room. ASME 17.1 Rule 105.5c, 106.1e, NEC 620-85.

7.  Install an adequate toe guard.

8.  Auto close is needed. Will work if button is pushed, need timer.

NI – NEEDS IMPROVEMENT 19 T-1054 FREIGHT ELEVATOR #3

OK – ACCEPTABLE FEBRUARY 2005 QEI / MAINTENANCE REVIEW