ProduCt:
Demountable acoustic ceiling in concealed grid system
with square 3.5x3.5 mm holes, c/c 8.33 mm
Material
Material:Perforated plasterboard
Board type:Ceiling tile
Length x width x thickness:
600 x 600 x 12.5
Edge:D+, concealed grid system
Perforation:Square 3.5x3.5mm holes, c/c 8.33 mm
Perforation to edge
Perforation percent:
17.2 %
Surface:Water-based acrylic paint
Colour:White NCS 0701 Y24R, RAL 9003; gloss 5
Attachment:24 mm T-grid system
Edge section:20x24 mm angled profile
19+11 x 13+19 mm cornice moulding
INSTALLATION
Suspension: Concealed grid system
- Distance between load-bearing sections c/c 600 mm.
- Distance between hangers and spacers ≤ 1500 mm.
- Distance from wall to first hanger and spacer ≤ 100 mm.
- Location of edge section: Lower edge of edge section = lower edge of finished ceiling.
- Screw spacing for attachment of edge section: max. 300mm c/c
- Socket load transferred to grid system.
PROPERTIES
Fire rating:A2-s1,d0
Acoustics:200 mm suspension, without mineral wool on reverse
125 Hz / 250 Hz / 500 Hz / 1000 Hz / 2000 Hz / 4000 Hz0.50 / 0.80 / 0.85 / 0.75 / 0.75 / 0.80
αw: 0.80
Light reflection in accordance with DIN 5036:
69.2%
Interior climate:Degasification: 10 days
Particle emission: Low
ProduCt:
Demountable acoustic ceiling in concealed grid system with perforation to edge, round Ø6mm holes, c/c 15 mm
Material
Material:Perforated plasterboard
Board type:Ceiling tile
Length x width x thickness:
600 x 600 x 12.5
Edge:D, concealed grid system
Perforation:Round 6 mm holes, c/c 15 mm, distance from edge of tile to centre of 1st perforation row 15 mm
Perforation percent:
11.95 %
Surface:Water-based acrylic paint
Colour:White NCS 0701 Y24R, RAL 9003; gloss 5
Attachment:24 mm T-grid system
Edge section:20x24 mm angled profile
19+11 x 13+19 mm cornice moulding
INSTALLATION
Suspension: Concealed grid system
- Distance between load-bearing sections c/c 600 mm.
- Distance between hangers and spacers ≤ 1500 mm.
- Distance from wall to first hanger and spacer ≤ 100 mm.
- Location of edge section: Lower edge of edge section = lower edge of finished ceiling.
- Screw spacing for attachment of edge section: max. 300mm c/c
- Socket load transferred to grid system.
PROPERTIES
Fire rating:A2-s1,d0
Acoustics:200 mm suspension, without mineral wool on reverse
125 Hz / 250 Hz / 500 Hz / 1000 Hz / 2000 Hz / 4000 Hz0.40 / 0.60 / 0.70 / 0.65 / 0.60 / 0.60
αw: 0.65
Light reflection in accordance with DIN 5036:
72.8%
Interior climate:Degasification: 10 days
Particle emission: Low
PRODUCT:
Demountable acoustic ceiling in concealed grid system
with round holes in 4 different diameters: Ø5, Ø8, Ø15 and Ø20 mm
in a “random” pattern.
Material
Material:Perforated plasterboard
Board type:Ceiling tile
Length x width x thickness:
600 x 600 x 12.5
Edge:D+, concealed grid system
Perforation:Round holes, Ø5, Ø8, Ø15 and Ø20 mm
Perforation to edge.
Perforation percent:
10.8 %
Surface:Water-based acrylic paint
Colour:White NCS 0701 Y24R, RAL 9003; gloss 5
Attachment:24 mm T-grid system
Edge section:20x24 mm angled profile
19+11 x 13+19 mm cornice moulding
INSTALLATION
Suspension: Concealed grid system
- Distance between load-bearing sections c/c 600 mm.
- Distance between hangers and spacers ≤ 1500 mm.
- Distance from wall to first hanger and spacer ≤ 100 mm.
- Location of edge section: Lower edge of edge section = lower edge of finished ceiling.
- Screw spacing for attachment of edge section: max. 300mm c/c
- Socket load transferred to grid system.
PROPERTIES
Fire rating:A2-s1,d0
Acoustics:200 mm suspension, without mineral wool on reverse
125 Hz / 250 Hz / 500 Hz / 1000 Hz / 2000 Hz / 4000 Hz0.40 / 0.55 / 0.60 / 0.60 / 0.50 / 0.50
αw: 0.60
Light reflection in accordance with DIN 5036:
72.2%
Interior climate:Degasification: 10 days
Particle emission: Low
PRODUCT:
Demountable acoustic ceiling in concealed grid system
with oval 4x14 mm holes, c/c 10/20 mm
Material
Material:Perforated plasterboard
Board type:Ceiling tile
Length x width x thickness:
600 x 600 x 12.5
Edge:D, concealed grid system
Perforation:Oval 4x14mm holes, c/c 10/20 mm
Perforation percent:
19.7 %
Surface:Water-based acrylic paint
Colour:White NCS 0701 Y24R, RAL 9003; gloss 5
Attachment:24 mm T-grid system
Edge section:20x24 mm angled profile
19+11 x 13+19 mm cornice moulding
INSTALLATION
Suspension: Concealed grid system
- Distance between load-bearing sections c/c 600 mm.
- Distance between hangers and spacers ≤ 1500 mm.
- Distance from wall to first hanger and spacer ≤ 100 mm.
- Location of edge section: Lower edge of edge section = lower edge of finished ceiling.
- Screw spacing for attachment of edge section: max. 300mm c/c
- Socket load transferred to grid system.
PROPERTIES
Fire rating:A2-s1,d0
Acoustics:200 mm suspension, without mineral wool on reverse
125 Hz / 250 Hz / 500 Hz / 1000 Hz / 2000 Hz / 4000 Hz0.35 / 0.65 / 0.70 / 0.70 / 0.70 / 0.80
αw: 0.70
Light reflection in accordance with DIN 5036:
70.9%
Interior climate:Degasification: 10 days
Particle emission: Low
PRODUCT:
Demountable acoustic ceiling in concealed grid system
with square 3x3 mm holes, c/c 8.33 mm
Material
Material:Perforated plasterboard
Board type:Ceiling tile
Length x width x thickness:
600 x 600 x 12.5
Edge:D, concealed grid system
Perforation:Square 3x3 mm holes, c/c 8.33 mm
Perforation percent:
10.2 %
Surface:Water-based acrylic paint
Colour:White NCS 0701 Y24R, RAL 9003; gloss 5
Attachment:24 mm T-grid system
Edge section: 20x24 mm angled profile
19+11 x 13+19 mm cornice moulding
INSTALLATION
Suspension: Concealed grid system
- Distance between load-bearing sections c/c 600 mm.
- Distance between hangers and spacers ≤ 1500 mm.
- Distance from wall to first hanger and spacer ≤ 100 mm.
- Location of edge section: Lower edge of edge section = lower edge of finished ceiling.
- Screw spacing for attachment of edge section: max. 300mm c/c
- Socket load transferred to grid system.
PROPERTIES
Fire rating:A2-s1,d0
Acoustics:200 mm suspension, without mineral wool on reverse
125 Hz / 250 Hz / 500 Hz / 1000 Hz / 2000 Hz / 4000 Hz0.40 / 0.55 / 0.65 / 0.60 / 0.60 / 0.55
αw: 0.65
Light reflection in accordance with DIN 5036:
72.1 %
Interior climate:Degasification: 10 days
Particle emission: Low
PRODUCT:
Demountable acoustic ceiling in concealed grid system
with square 12x12 mm holes, c/c 30 mm
Material
Material:Perforated plasterboard
Board type:Ceiling tile
Length x width x thickness:
600 x 600 x 12.5
Edge:D, concealed grid system
Perforation:Square 12x12 mm holes, c/c 30 mm
Perforation percent:
13.0 %
Surface:Water-based acrylic paint
Colour:White NCS 0701 Y24R, RAL 9003; gloss 5
Attachment:24 mm T-grid system
Edge section: 20x24 mm angled profile
19+11 x 13+19 mm cornice moulding
INSTALLATION
Suspension: Concealed grid system
- Distance between load-bearing sections c/c 600 mm.
- Distance between hangers and spacers ≤ 1500 mm.
- Distance from wall to first hanger and spacer ≤ 100 mm.
- Location of edge section: Lower edge of edge section = lower edge of finished ceiling.
- Screw spacing for attachment of edge section: max. 300mm c/c
- Socket load transferred to grid system.
PROPERTIES
Fire rating:A2-s1,d0
Acoustics:200 mm suspension, without mineral wool on reverse
125 Hz / 250 Hz / 500 Hz / 1000 Hz / 2000 Hz / 4000 Hz0.45 / 0.60 / 0.70 / 0.60 / 0.55 / 0.45
αw: 0.60
Light reflection in accordance with DIN 5036:
75.1 %
Interior climate:Degasification: 10 days
Particle emission: Low
PRODUCT:
Demountable acoustic ceiling in recessed grid system
with round 6 mm holes, c/c 15 mm
Material
Material:Perforated plasterboard
Board type:Ceiling tile
Length x width x thickness:
600 x 600 x 12.5
Edge:D, concealed grid system
Perforation:Round 6 mm holes, c/c 15 mm
Perforation percent:
10.2 %
Surface:Water-based acrylic paint
Colour:White NCS 0701 Y24R, RAL 9003; gloss 5
Attachment:24 mm T-grid system
Edge section: 20x24 mm angled profile
19+11 x 13+19 mm cornice moulding
INSTALLATION
Suspension: Concealed grid system
- Distance between load-bearing sections c/c 600 mm.
- Distance between hangers and spacers ≤ 1500 mm.
- Distance from wall to first hanger and spacer ≤ 100 mm.
- Location of edge section: Lower edge of edge section = lower edge of finished ceiling.
- Screw spacing for attachment of edge section: max. 300mm c/c
- Socket load transferred to grid system.
PROPERTIES
Fire rating:A2-s1,d0
Acoustics:200 mm suspension, without mineral wool on reverse
125 Hz / 250 Hz / 500 Hz / 1000 Hz / 2000 Hz / 4000 Hz0.45 / 0.65 / 0.80 / 0.65 / 0.55 / 0.45
αw: 0.60
Light reflection in accordance with DIN 5036:
72.8 %
Interior climate:Degasification: 10 days
Particle emission: Low
PRODUCT:
Demountable acoustic ceiling in concealed grid system without perforation
Material
Material:Non-perforated plasterboard
Board type:Ceiling tile
Length x width x thickness:
600 x 600 x 12.5
Edge:D, concealed grid system
Perforation:None
Surface:Water-based acrylic paint
Colour:White NCS 0701 Y24R, RAL 9003; gloss 5
Attachment:24 mm T-grid system
Edge section: 20x24 mm angled profile
19+11 x 13+19 mm cornice moulding
INSTALLATION
Suspension: Concealed grid system
- Distance between load-bearing sections c/c 600 mm.
- Distance between hangers and spacers ≤ 1500 mm.
- Distance from wall to first hanger and spacer ≤ 100 mm.
- Location of edge section: Lower edge of edge section = lower edge of finished ceiling.
- Screw spacing for attachment of edge section: max. 300mm c/c
- Socket load transferred to grid system.
PROPERTIES
Fire rating:A2-s1,d0
Acoustics:200 mm suspension, without mineral wool on reverse
125 Hz / 250 Hz / 500 Hz / 1000 Hz / 2000 Hz / 4000 Hz0.40 / 0.20 / 0.10 / 0.05 / 0.05 / 0.05
αw: 0.10
Light reflection in accordance with DIN 5036:
82.6 %
Interior climate:Degasification: 10 days
Particle emission: Low