February 22, 2012
Firmware Upgrade on ValueCut Products
Warning:
1.) A main board is required to be pre-programmed with a loader in order to become flash able for firmware uploading.
2.) Normally, before a new spare main board is ready to ship, a loader or even a firmware (smallest size of ordered model series) will be uploaded first on it. In case of functionality problem happening due to incorrect firmware version, please verify if the existing firmware on this main board is the desired one. A new program called (Firmware Upgrader) is a tool for users to easily upgrade firmware, followed by the steps listed below.
Step1.
Press indicated buttons by different port transmission listed on the table and open a “ValueCut File Uploader”.
Port to use / USB port / Serial portOperation / [Down] key + Power on / [CUT TEST] key + Power on
Step2.
Select a desired firmware and port on “ValueCut File Uploader” dialogue box, then press START for uploading.
Step3.
When update of the firmware is completed, machines reboot with a normal mode automatically.
Step4.
Initialize the setup information (Restore)
Press the [TOOL SELECT] key by “OFF LINE” mode to enter the Setup Menu, then select [Restore Default?] and press the [Enter] key.
Reboot the cutting plotter after performing “Restore”.
Reference video:http://youtu.be/k_E-gbNN4RE
Step5.
Re-enter the setup information
Factory default parameter information is attached under the machine.
Below are the items for setup. Numbers shown in each parenthesis below are the example numbers of this machine (serial# L75354).
AAS Offset (X= -0.6, Y= -0.5)
Scale Length (Length: 500 / 496.4 mm)
Width Length (Width: 500 / 500.2 mm)
AAS Offset setup steps
Press the [MICS] key by “OFF LINE” mode to enter the Setup Menu, then select [AAS Offset] and input each X, Y value.
Reference video:http://youtu.be/tXwvFrnH7Lg
Scale setup steps
Press the [MICS] key by “OFF LINE” mode to enter the Setup Menu, then select [Scale Length] and change the left number to [500]. Next change the right number to the value shown on the “Parameter record card”.
Reference video:http://youtu.be/azLflxVvPlI
1 / 2