OraQuick ADVANCE® Product Information Training Quiz

1. The complete storage temperature range of the OraQuick ADVANCETest Kit is

  1. 2-8º C; (35-46ºF)
  2. 2-27ºC; (35-80ºF)
  3. Comfortable room temperature – 15-27ºC; (59-99ºF)
  1. The complete storage temperature range of the OraQuick ADVANCE Kit Control is
  2. 2-8º C; (35-46ºF)
  3. 2-27ºC; (35-80ºF)
  4. Comfortable room temperature – 15-27ºC; (59-99ºF)
  1. The acceptable temperature range for performing the OraQuick ADVANCE Test is
  2. 2-8º C; (35-46ºF)
  3. 2-27ºC; (35-80ºF)
  4. Comfortable room temperature – 15-27ºC; (59-99ºF)
  1. According to the manufacturer’s instructions, the acceptable time to read the OraQuick ADVANCE Test Device result is
  2. 10 to 30 minutes
  3. 20 to 40 minutes
  4. 20 to 80 minutes
  5. 10 to 60 minutes
  1. The three possible OraQuick ADVANCE Test Device result outcomes are
  2. Reactive, non-reactive, borderline
  3. Reactive, non-reactive, inconclusive
  4. Reactive, non-reactive, weakly reactive
  5. Reactive, non-reactive, invalid
  1. When conducting an OraQuick ADVANCE Test Control, if the positive and/or negative control does not give the correct result(s), clients can still be tested with the OraQuick ADVANCE kits.
  2. True
  3. False
  1. The 2 holes in the back of the OraQuick ADVANCE Test Device must be covered after placing the device into the Developer Solution Vial.
  2. True
  3. False
  1. The built-in procedural control in the OraQuick ADVANCE Test Device is intended to confirm that the patient sample has moved past the Test (T) area.
  2. True
  3. False
  1. The OraQuick ADVANCE Test Device should not be removed from the Developer Solution Vial before reading the Test result.
  2. True
  3. False
  1. OraQuick ADVANCE is currently approved for use in the U.S. with fingerstick whole blood specimens only.
  2. True
  3. False
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)
  1. What is the result of the Test Device
  1. Non-Reactive (NR)
  2. Reactive (R)
  3. Invalid (INV)