Sagirev Guide Specification Section 07 42 93.33

August 11, 2017 PVC Soffit Panels

Sagiper North America Inc. Page 5

Copyright 2017 Sagiper North America Inc. Show Hidden Text for additional information.

CONTACT:

Sagiper North America Inc.

13179 - 156 Street NW, Edmonton, Alberta T5V 1V2

email

http://sagipernorthamerica.com/

·  Disclaimer: We provide this guide specification on an “as is” basis. While we intend for the guide specification content to be accurate, we do not guarantee its content or represent or warrant anything about its use. To the full extent permissible by applicable law, we disclaim all warranties, express or implied, including, but not limited to, noninfringement, implied warranties of merchantability and fitness for a particular purpose. We will not be liable for any damages of any kind arising from this guide specification use, including, but not limited to direct, indirect, incidental, punitive, and consequential damages.

·  This guide specification is written using terms (Owner, Consultant, etc.) found in CCDC contracts. For any other project contract type revise terms to suit.

·  When specifying for a particular project, if the Sagiper Sagirev products are for a non-soffit applications, consider renaming this Section to one of the following MasterFormat numbers/titles:

Section 06 64 19 – Prefinished Plastic Paneling

Section 09 54 29 – Suspended Plastic Ceilings

Section 09 78 19 –Plastic Interior Wall Paneling

1  General

1.1  Summary

1.1.1  *****This Section includes requirements for supply and installation of PVC [boards for exterior soffits] [boards for interior walls] [and] [boards for suspended interior ceilings] [boards for directly applied interior ceilings].

1.2  Related Requirements

1.2.1  *****Section 06 10 00 – Rough Carpentry: Plywood sheathing substrate

1.2.2  *****Section 06 16 43 – Gypsum Sheathing: Sheathing substrate

1.2.3  *****Section 07 21 13 – Board Insulation: Insulation as part of the exterior soffit assembly

1.2.4  *****Section 07 62 00 – Sheet Metal Flashing and Trim: Flashing and related work

1.2.5  Section 07 92 00 – Joint Sealants: Installation of sealants at site cut aluminum trims

1.2.6  *****Section 09 21 16 – Gypsum Board Assemblies: Gypsum sheathing substrate

1.2.7  *****Section 09 [51 13] – [Acoustic Panel] Ceilings: Suspension system supporting work of this Section at interior locations.

1.2.8  *****Division 21 – Fire Suppression: Coordination of sprinkler heads penetrating through panel materials.

1.2.9  *****Division 26 – Electrical: Coordination of electrical [outlet cover plate colour] [lighting fixture bezels] to match [soffits] [interior wall boards]

1.2.10  *****Drawing A [___]: Details of [exterior soffits] [interior walls] [ceilings]

1.3  REFERENCE STANDARDS

1.3.1  Deutsches Institut für Normung (DIN): DIN 53495 – Testing of Plastics; Determination of Water Absorption

1.3.2  *****Underwriters Laboratories Inc: CAN/ULC S102.2-10, Standard Method of Test for Surface Burning Characteristics of Flooring, Wall Coverings, and Miscellaneous Materials and Assemblies

1.4  Administrative Requirements

1.4.1  Coordination:

1.4.1.1  *****Coordinate installation of electrical outlets in [soffits] [interior partitions] [interior ceilings], and colour of cover plates to match [soffits] [interior partitions]
1.4.1.2  Coordinate work of Subcontractor’s with components penetrating ***** [soffits] [interior wall panels] [ceilings] to arrange for appropriate board movement allowances and trims at the intersection.
1.4.1.3  *****Coordinate dead load of decorative board ceiling materials supported by suspended ceiling assemblies. Refer to Section 09 51 13.

1.4.2  *****Schedule and coordinate installation of suspended ceiling to occur after completion of overhead mechanical and electrical work.

1.5  SUBMITTALS

1.5.1  Submit information in accordance with Section 01 33 00 – Submittal Procedures.

1.5.2  Action Submittals: Before starting work of this Section, submit the following:

1.5.2.1  Product Data: Submit manufacturer’s product data and installation instructions for each type of Product specified.
1.5.2.2  *****Samples for Initial Selection: Submit colour samples for plastic boards and accessories visible in the final installed work.
1.5.2.3  *****Samples for Verification: Submit actual samples, full profile width x approximately 200 mm long, of materials proposed for use on the Project for each profile and colour/pattern of board required.

1.5.3  Informational Submittals: During the course of the work submit the following:

SPECNOTE: The following item isn’t required on all projects.

1.5.3.1  *****Source Quality Control Submittals: Submit test results for fire testing in accordance with building code.

1.5.4  *****Sustainable Design Submittals: Coordinate project sustainable design requirements with Section [01 35 18 – LEED Requirements] [01 35 63 – Sustainability Certification Project Requirements].

1.5.5  Project Closeout Submittals:

1.5.5.1  Operation and Maintenance Data: Submit manufacturers’ instructions for repair and cleaning procedures. Include name of original installer and contact information, in accordance with Section ***** [01 78 23 – Operation and Maintenance Data].
1.5.5.2  Warranty Documentation: Submit manufacturer’s warranty documentation

1.5.6  Maintenance Material Submittals: Supply spare materials for the Owner’s maintenance use, in accordance with Section 01 78 43 – Spare Parts, and as follows:

1.5.6.1  Supply one (1) manufacturer’s touch-up pen for each colour on the Project.
1.5.6.2  ***** [1%] of installed boards in manufacturer’s standard maximum board lengths
1.5.6.3  ***** [One (1)] of each accessory and trim shape in manufacturer’s standard maximum lengths
1.5.6.4  Package materials with protective coverings and label with contents.
1.5.6.5  Locate at the Project site at a specific location as directed by Consultant or Owner.

1.6  Quality Assurance

1.6.1  Qualification Requirements: When requested by Consultant, submit proof of qualifications:

1.6.1.1  Installers: ***** [Three (3)] years [One (1) year] successful experience installing specified Products or similar products, with similar scope to this Project.

SPECNOTE: For projects with Sagiper interior finishes, insert applicable requirement for Flame Spread Rating and Smoke Development Classification to suit the project Occupancy Group, product location within the building, the particular building Element, and if the building is sprinklered or not sprinklered. Refer to building code Article 3.1.13.

1.6.2  *****Certifications:

1.6.2.1  Compliance Certification: Submit certificates from manufacturer indicating tested performance requirements required by Authorities Having Jurisdiction.

1.6.2.1.1  Independent Testing Report indicating compliance with CAN/ULC S102.2 for flame spread rating and smoke developed classification

SPECNOTE: Mock-ups increase the construction cost. Only specify mock-ups where there are very uncommon details or other uncommon circumstance.

1.6.3  *****Mock-Ups: Prepare mock-up[s] in accordance with Section [01 43 00 – Quality Assurance and Control] [014500 – Quality Control], and as follows:

1.6.3.1  Prepare a full size mock-up of plastic boards at the Project site for Consultant’s review. Include each type of material and accessory, one outside corner, ***** [and an intersection with exterior wall].

1.6.3.2  Once mock-up is accepted, maintain in an undisturbed condition throughout the construction period.

1.6.3.3  Mock-ups may remain as part of the final Work, if undamaged at time of ***** [Substantial Completion].

1.7  DELIVERY, STORAGE, AND HANDLING

1.7.1  Storage and Handling Requirements: Avoid exposure to ketones, cyclic ethers, and aromatic hydrocarbons (such as benzene and toluene).

1.7.1.1  *****Allow interior [wall] and [ceiling] boards to acclimatize to room temperature before beginning installation.

1.8  SITE CONDITIONS

1.8.1  Site Measurements: Verify dimensions by site measurements before fabrication and indicate measurements on shop drawings where plastic boards are indicated to fit between or around other construction. Coordinate fabrication schedule with construction progress to avoid delaying the Work.

1.8.2  Established Dimensions: Establish dimensions and proceed with ordering plastic boards without site measurements where site measurements cannot be made without delaying the Work. Coordinate construction to ensure that actual site dimensions correspond to established dimensions; allow for trimming and fitting.

1.8.3  Ambient Conditions: Proceed with installation ***** [at exterior locations when ambient temperatures are not below -10 degrees Celsius] [and] [at interior locations only after building envelope is complete and relative humidity typical of when building is in permanent operation]

1.9  WARRANTY

1.9.1  Manufacturer Warranty: ***** [Fifteen (15) year limited warranty for exterior soffits] [Limited lifetime warranty for interior locations]; from vinyl peeling, board warping, board splitting, and excessive discolouration.

2  Products

2.1  MANUFACTURERS

2.1.1  *****Basis-of-Design Materials: Products named in this Section were used as the basis-of-design for the Project. Additional manufacturers offering similar Products may be incorporated into the work of this Section if they meet the performance requirements established by the named Products, and when they submit substitution requests in accordance with Section 01 62 00.

2.1.2  Basis-of-Design Materials: Sagiper North America inc , Sagirev

2.1.3  *****Substitutions [will not be considered by request of the Owner] [will be considered during the bidding period when information is submitted to Consultant in accordance with Section 016200]

*****OR*****

2.1.4  *****Substitutions: Consultant may accept additional manufacturers with similar Products to the Acceptable Materials listed in this Section if substitutions meet the performance requirements established by the named Products, and when substitution requests are in accordance with Section 01 62 00.

2.1.5  Proposed substitutions of single-wall (non-extruded) plastic ***** [soffits] will not be considered.

2.2  Plastic Boards

SPECNOTE: For projects with Sagiper interior finishes, insert applicable requirement for Flame Spread Rating and Smoke Development Classification to suit the project Occupancy Group, product location within the building, the particular building Element, and if the building is sprinklered or not sprinklered. Refer to building code Article 3.1.13.

2.2.1  *****Regulatory Requirements: Provide interior [ceiling] [and] [wall] materials in compliance with the applicable building code, and as follows:

2.2.1.1  Panels tested in general conformance with CAN/ULC S102.2-10.

2.2.1.2  Flame Spread Ratings: ***** [___] [25] maximum

2.2.1.3  Smoke Developed Classification: ***** [___] [315] maximum

2.3  Performance Criteria

2.3.1  Board materials meeting the following requirements:

2.3.1.1  UV Resistance: 97% UV reflected minimum

2.3.1.2  Water Absorption (to DIN 53495): 0.04% maximum

2.3.1.3  Impact Resistance (H Sphere Hardness test): 120 N/mm2

2.3.1.4  Shear Strength: 5.5 KJ/m2

2.3.1.5  Coefficient of Expansion: 8x10-5K-1

2.4  Materials

SPECNOTE: Sagiper North America Inc, Sagirev 100 mm, 150 mm, and 200 mm profile section diagrams (NTS):

2.4.1  Extruded rigid board [soffits] [interior walls] [ceilings], with transparent PVDF layer over a transparent polymethylmethacrylate (PMMA) layer, over a decorative PMMA film with ***** [wood] [metallic] appearance factory applied on extruded PVC board substrate]

2.4.2  Board Profile: ***** [4” (100 mm)] [6” (150 mm)] [8” (200 mm)]

2.4.3  Board Length: ***** [19 feet (5790 mm)] [12 feet (3660 mm)] [Manufacturer’s maximum lengths to minimize site joints]

2.5  Finishes

2.5.1  *****Finish with Wood Appearance:

2.5.1.1  [REF 1 - Blonde Oak] [REF 2 - Port Redwood] [REF 3 -Chocolate Blackwood] [REF 4 - Espresso Blackwood] [REF 5 - White Oak] [REF 6 - Hazel Oak] [REF 7 - Brazilian Redwood] [REF 8 - Caramel Cedar] [REF 9 - Carmel Zebrawood] [REF 10 – Cherry Zebrawood] [REF 11 - Pine Zebrawood] [REF 12 - Titanium Coalwood] [REF 13 - Light Maple] [REF 14 – Walnut Blackwood]

*****OR*****

2.5.2  *****Finish with Metallic Appearance:

2.5.2.1  [REF 50 - Absolute Silver] [REF 60 - Absolute White] [REF 70] [REF 71] [REF 72] [REF 73] [REF 74] [REF 75] [REF 76] [REF 77] [REF 78] [REF 79 - Knotty Maple] [REF 80 - Mocha Redwood] [REF 81 - Chestnut Blackwood]

*****OR*****

2.5.3  *****Integral Colour Finish: [REF Blanco] [REF Marfim] [REF Madeira] [REF Medeira Escura]

2.5.4  Texture: ***** [Smooth for metallic finishes] [Embossed wood grain appearance]

2.6  ACCESSORIES

2.6.1  Manufacturer’s recommended PVC and aluminum accessories, with factory applied protective and decorative film, ***** [colour to match board finish] [contrasting colour as indicated on Drawings] [and as follows:]

2.6.1.1  ***** [Clip Crown Molding] [Outside Corner] [J-Mold “Punch Line”] [Cove trim] [Outer Corner] [Inner corner] [PVC Skirting with clip, 70 mm x 16 mm] [Punch Line] [H-Mold “Jointer”] [PVC Lath] [“Corner Guard”] [2-piece Cove Trim Clip] [Vent Strip]

2.6.2  Fasteners: ***** [Galvanized] [Stainless steel] for exterior locations [and interior high humidity locations], pan head wafer screws, length to penetrate [framing] [structural sheathing] by 19 mm minimum.

2.6.3  Sealant: Type as recommended by manufacturer, colour matching boards.

SPECNOTE: Sagiper North America Inc, Sagirev can be installed directly to a ceiling substrate, or installed onto a suspended ceiling system.

2.7  *****Suspension System

2.7.1  Metal Suspension System for Interior Ceilings: Direct hung metal suspension system, meeting requirements of ASTM C635/C635M for intermediate duty, concealed tee bar. Refer to Section 09 [51 13]

3  Execution

3.1  EXAMINATION

3.1.1  Verification of Conditions:

3.1.1.1  Verify substrate ***** [soffit framing] are braced or sheathed to resist racking loads in accordance with the building code.

3.1.1.2  Verify ***** [soffit framing] [interior wall substrate] has adequate fastener withdrawal resistance before beginning of installation of Products specified in this Section.

3.1.1.3  Beginning installation of Products specified in this Section will denote acceptance of site conditions.

3.2  PREPARATION

3.2.1  *****Prior to installation, randomly mix board bundles to maximize [wood grain] variation appearance and minimize pattern repeats.

3.2.2  Select boards of longest possible lengths.

SPECNOTE: Select one of the following installation types, or select multiple types as applicable to the project.

3.3  INSTALLATION – ***** [Boards for exterior soffits] [Interior wall Decorative paneling] [Interior Ceiling Finish with Concealed Suspension System] [Interior Ceiling Finish with Visible Grid Suspension System]

3.3.1  Install ***** [soffits] [interior ceilings] [interior wall boards] in accordance with manufacturer’s installation instructions, and as indicated in Contract Documents.

3.3.2  Securely attach ***** [soffits] [interior ceilings] [interior wall boards] using methods and materials recommended by board manufacturer [for wind load conditions at Project site].

3.3.3  Scribe and cut as required to fit abutting walls and adjacent surfaces, and to accommodate other materials where penetrating through boards. Secure boards and accessories in place, rigid, plumb and square, and as follows:

3.3.3.1  Install work with joints concealed behind corner trims and other manufacturer’s trim accessories.

3.3.3.2  Locate fasteners in center of elongated slots without binding boards, to allow for thermal movement. Allow for board expansion/contraction gaps as recommended by manufacturer, with consideration given to the temperature at time of installation.