OperatingmanualLaserlevel
Model: CUBE2-360
Manufacturer:ADAINSTRUMENTSAddress:
CUBE2-360
Table ofcontents
- Cautions...... 3
- Technicalrequirements...... 3
- Safety requirements andcare...... 6
- Orderworking...... 6
- Application...... 10
- Safetyprecaution...... 10
- Warranty...... 12
- Exceptions fromresponsibility...... 13
Appendix 1- “Certificate of acceptance andsale”Appendix 2- “Warrantycard”
2
- CAUTIONS
LaserlevelADACUBE2-360model-isanup-to-datefunctionalandmulti-prismdevicedesignedforindoorandoutdoor performance. The deviceemits:
one horizontal laser line (beam scan angle of360°)one vertical laser line (beam scan angle of360°);down pointlaser.
Do not look at the laserbeam!
Do not install the device on the eyelevel!
Before using the device, do read this operatingmanual!
- TECHNICALREQUIREMENTS
- FUNCTIONALDESCRIPTION
Emitting a horizontal and vertical laserline.
Quick self-leveling: when line accuracy is out of the range the laserlineflashesandthewarningsoundisproduced.Compensatorlockingsystem
for safe transportation. Intermediate compensator locking system for slopeoperation.
Indoor and outdoor performancefunction.3
2.2.FEATURES
- Laser lineson/off
- Indoor/outdoor operatingmode
- Battery compartment
- Tripod mount1/4’’
- Compensatorswitch
(ON/X/OFF)
- Vertical laserwindow
- Horizontal laserwindow
4
2.3.SPECIFICATIONS
LaserHorizontalline360°/verticalline360°
Lightsources2laserdiodeswithlaseremissionwavelengthof635nm
Laser safetyclassClass 2,<1mW
Accuracy±3 mm/10m
Self-levelingrange±4° Operating range with/withoutreceiver70/20m
Powersource3alkalinebatteries,AAtype
OperationtimeApprox. 15 hours, if everything ison
Tripodthread2х1/4”
Operatingtemperature-5°C+45°C
Weight390g
5
- SAFETY REQUIREMENTS ANDCARE
Follow safety requirements! Don’t face and stare at laserbeam!
LaserlevelisanaccurateInstrument,whichshouldbestoredandusedwithcare.
Avoid shaking and vibrations! Store the Instrument and It’s accessories only In the carryingcase. Incaseofhighhumidityandlowtemperature,dryouttheInstrumentandcleanItaftertheusage.
Do not store the Instrument at a temperature below -20°C and above 50°C, otherwise the Instrument canbeout ofaction.
Don’t put the Instrument Into the carrying case If the Instrument or case are wet. To avoid moisturecondensa-tion Inside the Instrument- dry out the case and laserInstrument!
Check regularly Instrumentadjustment!
Keep the lens clean and dry. To clean the Instrument use a soft cottonnapkin!
- ORDERWORKING
Cube 360 is a reliable and convenient instrument. It will be irreplaceable instrument for manyyears.
- Before use, remove battery compartment cover. Insert three batteries into battery compartment withproper
6
polarity, the put the coverback.
- Setthecompensatorlockinggrip5intoONposition,twolaserbeamswillbeon.If the switch is ON,that means the power is on and the compensator isworking.
Iftheswitch5isinintermediateposition,thatmeansthepowerisopened,thecompensationisstilllocked,butitwill not warn if you issue the slope. It’s thehand-mode.
If the switch 5 is OFF, that means that the instrument is off, the compensator is alsolocked.
- Pressbutton1onlyonce-horizontalbeamwillturnon.Pressthebutton1onemoretime-verticallaserbeamwill turn on. Again press the button 1 - horizontal and vertical beams will turnon.
- Pressbutton2once.Otdoormodeisactivated.Pressbutton2onemoretime.Theinstrumentbeginstoworkin indoormode.
7
Tochecktheaccuracyoflinelaserlevel
Tochecktheaccuracyoflinelaserlevel(slopeofplane)
Set up the instrument between two walls, the distance is 5m.Turn on the Line Laser, and markthepointofcrosslaserlineonthewall.Rotatetheinstrumentby180°andmarkthe
point of cross laser line on the wallagain.
Setuptheinstrument0,5-0,7mawayfromthewallandmake,asdescribedabove,thesamemasrks.Ifthedifference{a1-b2}and
{b1-b2}islessthenthevalueof“accuracy”(seespesifications),thereisnoneedincalibration.
Example:whenyouchecktheaccuracyofCrossLineLaserthedifference is {a1-a2}=5 mm and {b1-b2}=7 mm.Theinstrument’s error: {b1-b2}-{a1-a2}=7-5=2 mm. Now youcancomparethiserrorwithstandarderror.
If the accuracy of Laser level isn’t correspondingwithclaimedaccuracy,contacttheauthorizedservicecenter.
8
To checklevel
Choose a wall and set laser 5m away from the wall.Turn on the laser and cross laser line is marked A on thewall. FindanotherpointMonthehorizontalline,thedistanceis around 2.5m. Swivel the laser, and another cross pointof cross laser line is marked B. Please note the distanceof B to A should be5m.
Measure the distance between M to cross laser line.
To checkplumb
Choose a wall and set laser 5m away from the wall. Hanga plumb with the length 2.5 m on the wall. Turn on thelaser and make the vertical laser line meet the point of the plumb.
The accuracy of the line is in the range if the vertical line doesn’t exceed (up or down) the accuracy that is shown in the spesifications (e.g. ±3mm/10m). If the accuracy isn’t
corresponding with claimed accuracy, contact the authorized service center.9
5.APPLICATION
This cross line laser level generates visible laser beam allowing to make the following measurements: Height measurement, calibration of horizontal and vertical planes, right angles, vertical position of installations, etc. The cross line laser level is used for indoor performance to set zero marks, for marking out of bracing, installation of tingles, panel guides, tiling, etc. Laser device is often used for marking out in the process of furniture, shelf or mirror installation, etc. Laser device may be used for outdoor performance at distance within its operation range.
10
CARE ANDCLEANING
Pleasehandlemeasuringinstrumentwithcare.Cleanwithsoftclothonlyafteranyuse.Ifnecessarydampclothwithsomewater.Ifinstrumentiswetcleananddryitcarefully.Packituponlyifitisperfectlydry.Transportinoriginalcontainer/caseonly.Note:DuringtransportOn/Offcompensatorlock(5)mustbesettoposition“OFF”.Disregardmayleadtodamageofcompen-sator.
SPECIFIC REASONS FOR ERRONEOUS MEASURING RESULTS
•Measurements through glass or plasticwindows;
•Dirty laser emittingwindow;
•After instrument has been dropped or hit. Please check theaccuracy.
•Largefluctuationoftemperature:ifinstrumentwillbeusedincoldareasafterithasbeenstoredinwarmareas(orthe other way round) please wait some minutes before carrying outmeasurements.
ELECTROMAGNETICACCEPTABILITY(EMC)
•It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigationsystems);
•willbedisturbedbyotherinstruments(e.g.intensiveelectromagneticradiationnearbyindustrialfacilitiesorradiotrans-
mitters).11
LASERCLASSIFICATION
Theinstrumentisalaserclass2laserproductaccortdingtoDINIEC60825-1:2007.Itisallowedtouseunitwithoutfurther safetyprecautions.
SAFETYINSTRUCTIONS
Pleasefollowupinstructionsgiveninoperators’manual.
Donotstareintobeam.Laserbeamcanleadtoeyeinjury(evenfromgreaterdistances).Donotaimlaserbeamatpersonsoranimals.
Thelaserplaneshouldbesetupaboveeyelevelofpersons.Use the instrument for measuring jobsonly.
Donotopeninstrumenthousing.Repairsshouldbecarriedoutbyauthorizedworkshops only. Pleasecontactyour
localdealer.
Do not remove warning labels or safetyinstructions.Keep instrument away fromchildren.
Donotuseinstrumentinexplosiveenvironment.
WARRANTY
Thisproductiswarrantedbythemanufacturertotheoriginalpurchasertobefreefromdefectsinmaterialandwork-manshipundernormaluseforaperiodoftwo(2)yearsfromthedateofpurchase.
12
Duringthewarrantyperiod,anduponproofofpurchase,theproductwillberepairedorreplaced(withthesameorsimilarmodelatmanufacturesoption),withoutchargeforeitherpartsoflabour.
Incaseofadefectpleasecontactthedealerwhereyouoriginallypurchasedthisproduct.Thewarrantywillnotapplytothis productifithasbeenmisused,abusedoraltered.Withiutlimitingtheforegoing,leakageofthebattery,bendingordroppingtheunitarepresumedtobedefectsresultingfrommisuseorabuse.
EXCEPTIONS FROMRESPONSIBILITY
Theuserofthisproductisexpectedtofollowtheinstructionsgiveninoperators’manual.
Althoughallinstrumentsleftourwarehouseinperfectconditionandadjustmenttheuserisexpectedtocarryoutperiodicchecksoftheproduct’saccuracyandgeneralperformance.
Themanufacturer,oritsrepresentatives,assumesnoresponsibilityofresultsofafaultyorintentionalusageormisuseinclud-inganydirect,indirect,consequentialdamage,andlossofprofits.
Themanufacturer,oritsrepresentatives,assumesnoresponsibilityforconsequentialdamage,andlossofprofitsbyanydisaster(earthquake,storm,flood...),fire,accident,oranactofathirdpartyand/orausageinotherthanusualconditions.Themanufacturer,oritsrepresentatives,assumesnoresponsibilityforanydamage,andlossofprofitsduetoachangeofdata,lossofdataandinterruptionofbusinessetc.,causedbyusingtheproductoranunusableproduct.
Themanufacturer,oritsrepresentatives,assumesnoresponsibilityforanydamage,andlossofprofitscausedbyusageotherthsn explained in the users’manual.
Themanufacturer,oritsrepresentatives,assumesnoresponsibilityfordamagecausedbywrongmovementoractiondueto
connecting with otherproducts.13
WARRANTYDOESN’TEXTENDTOFOLLOWINGCASES:
- If the standard or serial product number will be changed, erased, removed or wil beunreadable.
- Periodic maintenance, repair or changing parts as a result of their normalrunout.
- Alladaptationsandmodificationswiththepurposeofimprovementandexpansionofnormalsphereofproductap-plication,mentionedintheserviceinstruction,withouttentativewrittenagreementoftheexpertprovider.
- Service by anyone other than an authorized servicecenter.
- Damagetoproductsorpartscausedbymisuse,including,withoutlimitation,misapplicationornrgligenceoftheterms of serviceinstruction.
- Power supply units, chargers, accessories, wearingparts.
- Products,damagedfrommishandling,faultyadjustment,maintenancewithlow-qualityandnon-standardmaterials,presence of any liquids and foreign objects inside theproduct.
- Acts of God and/or actions of thirdpersons.
- Incaseofunwarrantedrepairtilltheendofwarrantyperiodbecauseofdamagesduringtheoperationoftheproduct,it’s transportation and storing, warranty doesn’tresume.
WARRANTYCARD
Name and model of theproduct
Serialnumberdate ofsale
Name of commercialorganizationstamp of commercialorganizationWarrantyperiodfortheinstrumentexplotationis24monthsafterthedateoforiginalretailpurchase.
Duringthiswarrantyperiodtheowneroftheproducthastherightforfreerepairofhisinstrumentincaseofmanufacturingdefects.
Warrantyisvalidonlywithoriginalwarrantycard,fullyandclearfilled(stampormarkofthrsellerisobligatory).
Technicalexaminationofinstrumentsforfaultidentificationwhichisunderthewarranty,ismadeonlyintheauthorizedservicecenter.
Innoeventshallmanufacturerbeliablebeforetheclientfordirectorconsewuentialdamages,lossofprofitoranyotherdamagewhichoccur in the result of the instrumentoutage.
Theproductisreceivedinthestateofoperability,withoutanyvisibledamages,infullcompleteness.Itistestedinmypresence.Ihavenocomplaintstotheproductquality.Iamfamiliarwiththeconditionsofqarrantyserviceandiagree.
purchasersignature
Beforeoperatingyoushouldreadserviceinstruction!
Ifyouhaveanyquestionsaboutthewarrantyserviceandtechnicalsupportcontactsellerofthisproduct
Certificate of acceptance andsale
№
name and model of theinstrument
Correspondsto
designation of standard and technicalrequirements
Data ofissue Stamp of quality controldepartment
Price
SoldDate ofsale
name of commercialestablishment