  1. CAUTIONS

LaserlevelADACUBE2-360model-isanup-to-datefunctionalandmulti-prismdevicedesignedforindoorandoutdoor performance. The deviceemits:

one horizontal laser line (beam scan angle of360°)one vertical laser line (beam scan angle of360°);down pointlaser.

Do not look at the laserbeam!

Do not install the device on the eyelevel!

Before using the device, do read this operatingmanual!

  1. TECHNICALREQUIREMENTS
  2. FUNCTIONALDESCRIPTION

Emitting a horizontal and vertical laserline.

Quick self-leveling: when line accuracy is out of the range the laserlineflashesandthewarningsoundisproduced.Compensatorlockingsystem

for safe transportation. Intermediate compensator locking system for slopeoperation.

Indoor and outdoor performancefunction.3

2.2.FEATURES

  1. Laser lineson/off
  2. Indoor/outdoor operatingmode
  3. Battery compartment
  4. Tripod mount1/4’’
  5. Compensatorswitch

(ON/X/OFF)

  1. Vertical laserwindow
  2. Horizontal laserwindow

4

2.3.SPECIFICATIONS

LaserHorizontalline360°/verticalline360°

Lightsources2laserdiodeswithlaseremissionwavelengthof635nm

Laser safetyclassClass 2,<1mW

Accuracy±3 mm/10m

Self-levelingrange±4° Operating range with/withoutreceiver70/20m

Powersource3alkalinebatteries,AAtype

OperationtimeApprox. 15 hours, if everything ison

Tripodthread2х1/4”

Operatingtemperature-5°C+45°C

Weight390g

5

  1. SAFETY REQUIREMENTS ANDCARE

Follow safety requirements! Don’t face and stare at laserbeam!

LaserlevelisanaccurateInstrument,whichshouldbestoredandusedwithcare.

Avoid shaking and vibrations! Store the Instrument and It’s accessories only In the carryingcase. Incaseofhighhumidityandlowtemperature,dryouttheInstrumentandcleanItaftertheusage.

Do not store the Instrument at a temperature below -20°C and above 50°C, otherwise the Instrument canbeout ofaction.

Don’t put the Instrument Into the carrying case If the Instrument or case are wet. To avoid moisturecondensa-tion Inside the Instrument- dry out the case and laserInstrument!

Check regularly Instrumentadjustment!

Keep the lens clean and dry. To clean the Instrument use a soft cottonnapkin!

  1. ORDERWORKING

Cube 360 is a reliable and convenient instrument. It will be irreplaceable instrument for manyyears.

  1. Before use, remove battery compartment cover. Insert three batteries into battery compartment withproper

6

polarity, the put the coverback.

  1. Setthecompensatorlockinggrip5intoONposition,twolaserbeamswillbeon.If the switch is ON,that means the power is on and the compensator isworking.

Iftheswitch5isinintermediateposition,thatmeansthepowerisopened,thecompensationisstilllocked,butitwill not warn if you issue the slope. It’s thehand-mode.

If the switch 5 is OFF, that means that the instrument is off, the compensator is alsolocked.

  1. Pressbutton1onlyonce-horizontalbeamwillturnon.Pressthebutton1onemoretime-verticallaserbeamwill turn on. Again press the button 1 - horizontal and vertical beams will turnon.
  2. Pressbutton2once.Otdoormodeisactivated.Pressbutton2onemoretime.Theinstrumentbeginstoworkin indoormode.

7

Tochecktheaccuracyoflinelaserlevel

Tochecktheaccuracyoflinelaserlevel(slopeofplane)

Set up the instrument between two walls, the distance is 5m.Turn on the Line Laser, and markthepointofcrosslaserlineonthewall.Rotatetheinstrumentby180°andmarkthe

point of cross laser line on the wallagain.

Setuptheinstrument0,5-0,7mawayfromthewallandmake,asdescribedabove,thesamemasrks.Ifthedifference{a1-b2}and

{b1-b2}islessthenthevalueof“accuracy”(seespesifications),thereisnoneedincalibration.

Example:whenyouchecktheaccuracyofCrossLineLaserthedifference is {a1-a2}=5 mm and {b1-b2}=7 mm.Theinstrument’s error: {b1-b2}-{a1-a2}=7-5=2 mm. Now youcancomparethiserrorwithstandarderror.

If the accuracy of Laser level isn’t correspondingwithclaimedaccuracy,contacttheauthorizedservicecenter.

8

To checklevel

Choose a wall and set laser 5m away from the wall.Turn on the laser and cross laser line is marked A on thewall. FindanotherpointMonthehorizontalline,thedistanceis around 2.5m. Swivel the laser, and another cross pointof cross laser line is marked B. Please note the distanceof B to A should be5m.

Measure the distance between M to cross laser line.

To checkplumb

Choose a wall and set laser 5m away from the wall. Hanga plumb with the length 2.5 m on the wall. Turn on thelaser and make the vertical laser line meet the point of the plumb.

The accuracy of the line is in the range if the vertical line doesn’t exceed (up or down) the accuracy that is shown in the spesifications (e.g. ±3mm/10m). If the accuracy isn’t

corresponding with claimed accuracy, contact the authorized service center.9

5.APPLICATION

This cross line laser level generates visible laser beam allowing to make the following measurements: Height measurement, calibration of horizontal and vertical planes, right angles, vertical position of installations, etc. The cross line laser level is used for indoor performance to set zero marks, for marking out of bracing, installation of tingles, panel guides, tiling, etc. Laser device is often used for marking out in the process of furniture, shelf or mirror installation, etc. Laser device may be used for outdoor performance at distance within its operation range.

10

CARE ANDCLEANING

Pleasehandlemeasuringinstrumentwithcare.Cleanwithsoftclothonlyafteranyuse.Ifnecessarydampclothwithsomewater.Ifinstrumentiswetcleananddryitcarefully.Packituponlyifitisperfectlydry.Transportinoriginalcontainer/caseonly.Note:DuringtransportOn/Offcompensatorlock(5)mustbesettoposition“OFF”.Disregardmayleadtodamageofcompen-sator.

SPECIFIC REASONS FOR ERRONEOUS MEASURING RESULTS

•Measurements through glass or plasticwindows;

•Dirty laser emittingwindow;

•After instrument has been dropped or hit. Please check theaccuracy.

•Largefluctuationoftemperature:ifinstrumentwillbeusedincoldareasafterithasbeenstoredinwarmareas(orthe other way round) please wait some minutes before carrying outmeasurements.

ELECTROMAGNETICACCEPTABILITY(EMC)

•It cannot be completely excluded that this instrument will disturb other instruments (e.g. navigationsystems);

•willbedisturbedbyotherinstruments(e.g.intensiveelectromagneticradiationnearbyindustrialfacilitiesorradiotrans-

mitters).11

LASERCLASSIFICATION

Theinstrumentisalaserclass2laserproductaccortdingtoDINIEC60825-1:2007.Itisallowedtouseunitwithoutfurther safetyprecautions.

SAFETYINSTRUCTIONS

Pleasefollowupinstructionsgiveninoperators’manual.

Donotstareintobeam.Laserbeamcanleadtoeyeinjury(evenfromgreaterdistances).Donotaimlaserbeamatpersonsoranimals.

Thelaserplaneshouldbesetupaboveeyelevelofpersons.Use the instrument for measuring jobsonly.

Donotopeninstrumenthousing.Repairsshouldbecarriedoutbyauthorizedworkshops only. Pleasecontactyour

localdealer.

Do not remove warning labels or safetyinstructions.Keep instrument away fromchildren.

Donotuseinstrumentinexplosiveenvironment.

WARRANTY

Thisproductiswarrantedbythemanufacturertotheoriginalpurchasertobefreefromdefectsinmaterialandwork-manshipundernormaluseforaperiodoftwo(2)yearsfromthedateofpurchase.

12

Duringthewarrantyperiod,anduponproofofpurchase,theproductwillberepairedorreplaced(withthesameorsimilarmodelatmanufacturesoption),withoutchargeforeitherpartsoflabour.

Incaseofadefectpleasecontactthedealerwhereyouoriginallypurchasedthisproduct.Thewarrantywillnotapplytothis productifithasbeenmisused,abusedoraltered.Withiutlimitingtheforegoing,leakageofthebattery,bendingordroppingtheunitarepresumedtobedefectsresultingfrommisuseorabuse.

EXCEPTIONS FROMRESPONSIBILITY

Theuserofthisproductisexpectedtofollowtheinstructionsgiveninoperators’manual.

Althoughallinstrumentsleftourwarehouseinperfectconditionandadjustmenttheuserisexpectedtocarryoutperiodicchecksoftheproduct’saccuracyandgeneralperformance.

Themanufacturer,oritsrepresentatives,assumesnoresponsibilityofresultsofafaultyorintentionalusageormisuseinclud-inganydirect,indirect,consequentialdamage,andlossofprofits.

Themanufacturer,oritsrepresentatives,assumesnoresponsibilityforconsequentialdamage,andlossofprofitsbyanydisaster(earthquake,storm,flood...),fire,accident,oranactofathirdpartyand/orausageinotherthanusualconditions.Themanufacturer,oritsrepresentatives,assumesnoresponsibilityforanydamage,andlossofprofitsduetoachangeofdata,lossofdataandinterruptionofbusinessetc.,causedbyusingtheproductoranunusableproduct.

Themanufacturer,oritsrepresentatives,assumesnoresponsibilityforanydamage,andlossofprofitscausedbyusageotherthsn explained in the users’manual.

Themanufacturer,oritsrepresentatives,assumesnoresponsibilityfordamagecausedbywrongmovementoractiondueto

connecting with otherproducts.13

WARRANTYDOESN’TEXTENDTOFOLLOWINGCASES:

  1. If the standard or serial product number will be changed, erased, removed or wil beunreadable.
  1. Periodic maintenance, repair or changing parts as a result of their normalrunout.
  1. Alladaptationsandmodificationswiththepurposeofimprovementandexpansionofnormalsphereofproductap-plication,mentionedintheserviceinstruction,withouttentativewrittenagreementoftheexpertprovider.
  1. Service by anyone other than an authorized servicecenter.
  1. Damagetoproductsorpartscausedbymisuse,including,withoutlimitation,misapplicationornrgligenceoftheterms of serviceinstruction.
  1. Power supply units, chargers, accessories, wearingparts.
  1. Products,damagedfrommishandling,faultyadjustment,maintenancewithlow-qualityandnon-standardmaterials,presence of any liquids and foreign objects inside theproduct.
  1. Acts of God and/or actions of thirdpersons.
  1. Incaseofunwarrantedrepairtilltheendofwarrantyperiodbecauseofdamagesduringtheoperationoftheproduct,it’s transportation and storing, warranty doesn’tresume.

WARRANTYCARD

Name and model of theproduct

Serialnumberdate ofsale

Name of commercialorganizationstamp of commercialorganizationWarrantyperiodfortheinstrumentexplotationis24monthsafterthedateoforiginalretailpurchase.

Duringthiswarrantyperiodtheowneroftheproducthastherightforfreerepairofhisinstrumentincaseofmanufacturingdefects.

Warrantyisvalidonlywithoriginalwarrantycard,fullyandclearfilled(stampormarkofthrsellerisobligatory).

Technicalexaminationofinstrumentsforfaultidentificationwhichisunderthewarranty,ismadeonlyintheauthorizedservicecenter.

Innoeventshallmanufacturerbeliablebeforetheclientfordirectorconsewuentialdamages,lossofprofitoranyotherdamagewhichoccur in the result of the instrumentoutage.

Theproductisreceivedinthestateofoperability,withoutanyvisibledamages,infullcompleteness.Itistestedinmypresence.Ihavenocomplaintstotheproductquality.Iamfamiliarwiththeconditionsofqarrantyserviceandiagree.

purchasersignature

Beforeoperatingyoushouldreadserviceinstruction!

Ifyouhaveanyquestionsaboutthewarrantyserviceandtechnicalsupportcontactsellerofthisproduct

Certificate of acceptance andsale

name and model of theinstrument

Correspondsto

designation of standard and technicalrequirements

Data ofissue Stamp of quality controldepartment

Price

SoldDate ofsale

name of commercialestablishment