Electronic timers, modular design 17.5 mm width
Revision 1.0
Content1.0General information / introduction
2.0Product features / product functions
3.0Conformance / standards
4.0Approvals / certificates / marks
5.0Technical data
6.0Mechanical requirements
7.0Quality requirements
8.0Documentation
9.0Start up and adjustment
10.0Accessories
1.0General This specification guide covers the general requirements for design,
information/manufacturing and installation of electronic timers.
Introduction
2.0Product features/The devices shall be designed for all time-delayed switching
product functions operations in control, starting, protective and regulating circuits. They shall be available with different timing functions or modes of operation.
The timers shall be able to provide the following time delay functions (single function and multifunction devices):
-ON-delay/ Delay on make
-OFF-delay, with auxiliary voltage/ Delay on break
-Impulse-ON/ Interval
-Pulse former/ Single shot
-Impulse-OFF, with auxiliary voltage/ Trailing edge interval
-Flasher, starting with “ON”/ Recycling equal times-ON first
-Flasher, starting with “OFF”/ Recycling equal times-OFF first
-Pulse generator starting with “ON” or starting with “OFF”/ Recycling unequal times
The desired function shall be able to be pre-selected with a front-sided rotary switch with the multifunction devices and the desired time delay shall be able to be set by a potentiometer with a direct reading scale.
Each device shall be able to operate on 7 time ranges (0.05s-100h).
A parallel load to the control input shall be possible.
The product shall be provided with the following LED indications:
-Output relay energized (preferably red LED)
-Supply voltage (preferably green LED)
The timers shall be ABB type CT-D range or pre-approved equal.
-ON-delay/ Delay on make
(CT-ERD, CT-MFD)
-OFF-delay, with auxiliary voltage/ Delay on break
(CT-AHD, CT-MFD)
-Impulse-ON/ Interval
(CT-VWD, CT-MFD)
-Pulse former/ Single shot
(CT-MFD)
-Impulse-OFF, with auxiliary voltage/ Trailing edge interval
(CT-MFD)
-Flasher, starting with “ON”/ Recycling equal times-ON first
(CT-EBD, CT-MFD)
-Flasher, starting with “OFF”/ Recycling equal times-OFF first
(CT-MFD)
-Pulse generator starting with “ON” or starting with “OFF”/ Recycling unequal times
(CT-TGD)
3.0Conformance/The timers shall be designed, manufactured and tested in accordance
standardswith the latest editions of applicable IEC and EN standards.
Product standard:IEC 61812-1 10.1996, EN 611812-1+ A11/8.1999
DIN VDE 0435 part 2021
Electromagnetic compatibility:
ESD IEC 61000-4-2, EN 61000-4-2
HF radiation resistanceIEC 61000-4-3, EN 61000-4-3
BurstIEC 61000-4-4, EN 61000-4-4
SurgeIEC 1000-4-5, EN 61000-4-5
HF line emission IEC 1000-4-6, EN 61000-4-6
Isolation:
Rated insulation voltageIEC 50175
Rated impulse withstand voltage IEC 664 – 4kV
Pollution category IEC 50175 – 2
Overvoltage categoryIEC 50175 – III
Environmental testsIEC 68-2-30
4.0 Approvals / MarksThe timers shall be approved and/ or certified by the following organizations:
-Underwriters Laboratories (cULus)
-GOST
and shall have the following marks:
-CE
-C-Tick
5.0 Technical dataThe timers shall be rated in accordance with the following
specifications:
Rated supply voltage 24-240 V AC
24-48 V DC
Frequency, AC supply50/60 Hz or DC (0 Hz) Number of output contacts 1 c/o
Rated switching voltage (IEC 60947-1)250 V AC
Rated switching current:
AC12 (resistive) @ 230 V 6 A
AC15 (inductive) @ 230 V3 A
DC12 (resistive) @ 24 V6 A
DC13 (inductive) @ 24 V2 A
Operating temperature range-20 °C … +60 °C
Storage temperature range-40 °C … +85 °C
6.0 MechanicalThe timer should be realized in a 17.5 mm wide enclosure, possible
requirements to be mounted on DIN rail according to EN 50022.
The connection terminals should be able to accept wires in the size of 2 x 1.5 mm² (2 x 16 AWG) with wire end ferrule or 2 x 2.5 mm² (2 x 14 AWG) without wire end ferrule.
The mounting position of the device in a cabinet should not be limited. According to IEC 68-2-6 the timers should have a mechanical resistance of 6 g and an operational reliability of 4 g.
7.0 QualityThe vendor shall be certified in accordance to ISO 9001 (quality
requirementsmanagement system) and ISO 14001 (environmental certification).
A complete environmental product declaration (EPD) shall be
available upon request. The EPD shall describe the material
used for the timer, energy consumption, losses, etc.
The product shall be functionally tested prior to shipment to assure
proper operation per specification.
8.0 DocumentationThe device shall be shipped with an operation and instruction sheet
including functional diagrams, connection diagrams and set up
information.
9.0 Startup andStartup procedures shall be intuitive and simple enough so as not to
adjustmentrequire factory assistance or training. All adjustments shall be made from the front of the timer by using rotating switches with direct reading scales.
10.0 AccessoriesAs accessory a manual setting tool should be available.
1/3