MEDIUM VOLTAGE INVERTER DATA SHEET / Proforma: / Proposal: / Date:
Purchaser: / Phone:
City: / Country: / Fax:
Technical Contact: / Type of industry: / Email:
Application: / Website:
Technical Specification (document number):
WEG Branch / Distributor: / Email:
Contact Person: / Phone: / Fax:
I. Motor Data:
1. Identification / 2. Manufacturer / 3. Rated Power / 4. Number of Poles
Existing / WEG / kW / IV poles
In production / Other: / HP / Other:

5. Voltage

/ 6. Type /

7. Rated Current

/ 9. Temperature Detectors
2300 VAC / IEC - N / Amps / Thermostat
3300 VAC /

NEMA B

/

8. Ventilation

/ PTC
4160 VAC /

NEMA D

/ Self ventilated / Pt-100
Other: / Forced: V / sensors per Bearing
kW / HP / sensors per Winding
10. Speed Feedback / 11. Space Heater / 12. Speed Range / 13. Overload
No / 110 VAC / W / Min.: rpm Hz / %In / %Cn
Encoder / 230 VAC / W / Rated: rpm Hz / Duration: seconds
Other: / Other: / W / Max.: rpm Hz / Frequency: /hour
14. Technical Observations:
II. Inverter Data ---- Quantity: ---- Model:

15. Type of Drive

/

16. Input Voltage

/ 17. Rectification /

18. Control Supply Voltage

MVW01 / 2300 VAC / 12 pulses / 220 VAC 380 VAC
MVW01C - Compact / 3300 VAC / 18 pulses / 400 VAC 440 VAC
4160 VAC / Other: / 480 VAC Other:
/ Other:
19. Installation
/

20. Line Frequency

/

21. Cable Connection

/ 22. Assembly Type
Indoor / 50 Hz / Incoming: Bottom Top / Against the wall
Outdoor / 60 Hz / Outgoing: Bottom Top / Other:
23. Panel Ventilation /

24. Degree of Protection

/

25. Ambient Conditions

Standard / IP-41 / Altitude: less than 1000 m Other:
100% redundant / IP-42 / Temperature: 0…40°C Other:
N + 1 redundancy /
Humidity: 5…90% Other:
26. Finishing Color /

27. Panel Tests

/ Seismicity: None Zone:
Munsell 5PB7/4 (doors) and 5PB2/6 (base, roof and shutter) / Standard (non-witnessed) / Non-aggressive
Witnessed inspection / Aggressive (describe):
RAL 7032 / Special tests:
Other:

Notes:

1) Filling out the blue fields is mandatory.

2) The options in bold style indicate the WEG standard.

28. Output Filters

/ 29. Operation Form /

30. Operation System

/

31. Communication (Fieldbus)

None

/

Manual

/ Unidirectional / Profibus DP

Load Reactor

/ Automatic / Bidirectional / DeviceNet
dV/dt Filter / Local / Without braking / Modbus-RTU
Sinus Filter / Remote / With dynamic braking / Ethernet/IP
With bypass / With regenerative braking
32. Panel to Motor Distance /

33. Speed Range

/ 34. Other
Less than 100 m / Min.: rpm Hz / Braking Resistor:
Other: / Max.: rpm Hz / Ω / W / %ED
Other:

35. Control and Signaling

/

36. Instrumentation

Loc. / Rem. / Loc. / Rem.
Start / Stop Pushbuttons / Pt-100 relay --- qty. of probes:
Emergency Stop Pushbutton / PTC relay
“VFD Ready” Pilot light – Color: / Analog voltmeter on the input --- qty.:
“VFD Fault” Pilot light – Color: / Digital voltmeter on the input --- qty.:
“VFD Running” Pilot light – Color: / Phase selector voltmeter
2 Positions Select Switch (Local / Remote) / Analog ammeter for input current --- qty.:
3 Positions Select Switch (Manual / Off / Auto) / Digital ammeter for motor current --- qty.:
Speed Up / Speed Down Pushbuttons / Phase selector ammeter
Speed Variation – 4…20mA / Wattmeter on the input
Other: / Wattmeter on the output
Other: / Analog tachometer for motor speed in rpm
Other: / Digital tachometer for motor speed in rpm
Other: / Digital speed indicator
Other: / Other:

37. Panel Heating and Lighting Modules

/ 38. Project Information

A50 – Space heater 50 W, with single-phase power outlet

/ Drawings for acknowledge
A51 – Space heater 50 W, w/ thermostat and single-phase outlet /

Drawings for approval

A51 – Space heater 50 W, w/ CE Certified thermostat and outlet / Certified drawings
A60 – Lighting module with 40 W incandescent lamp / Certification from external organization:
A61 – Lighting module with 9 W fluorescent lamp / Materials supplied by the customer:
1) - qty.:
2) - qty.:
3) - qty.:
A61 – CE Certified lighting module with 11 W fluorescent lamp
Voltage: 110 VAC 230 VAC Other:
39. Additional Instructions:
III. Phase-shifting Transformer Data ---- Quantity:

40. Primary Voltage

/

41. Number of Pulses:

/

42. Insulation Type

/

43. Additional Instructions:

13,8 kV / 12 pulses / Oil type
11,0 kV / 18 pulses / Dry type
6,6 kV / Other:
Other:
IV. Switchgear Data ---- Quantity:

44. Protective Switching Devices

/

45. Additional Instructions:

Circuit Breaker
Disconnect Switch + Fuses + Main Contactor
Other:

Notes:

1) Filling out the blue fields is mandatory.

2) The options in bold style indicate the WEG standard.

3) In fields 35 and 36 fields, "Loc." means mounted on the panel door and "Rem." means that terminal blocks are available for user installation.

WEG Equipamentos Elétricos S/A

Av. Prefeito Waldemar Grubba, 3000 - 89256-900 - Jaraguá do Sul - SC - Fone (47) 3276-4000 - Fax (47) 3276-4010 – www.weg.net 1/2