071 *MATERIAL SAFETY DATA SHEET* Page 1 of 2
______
MEDICAL EMERGENCY ONLY, 24 HOURS SERVICE: 1-800-328-0026
ECOLAB INC Ecolab Center Product Information: 1-612-293-2233
St. Paul MN 55102 Date of Issue: January 20, 1998
======
1.0 IDENTIFICATION /
______
1.1 Product Name: PHOSPHORIC ACID (REAGENT #071)
1.2 Product Type: Acid Test Kit Reagent
1.3 Hazard Rating: Health - 2 Fire - 0 Reactivity - 2
_ _ _
______
++ SARA 313 Toxic Chemicals, If Present, Are Preceded by "#" ++
------
2.0 HAZARDOUS COMPONENTS / (mg/m3)
______
% PEL TWA
______
2.1 # Phosphoric acid 7664-38-2 (STEL = 3 mg/m3) 50 1 1
------
STEL = 15 Minute Average in Air PEL = OSHA 8 Hour Average in Air
______
3.0 PHYSICAL DATA /
______
3.1 Appearance: Clear, odorless liquid
3.2 Solubility in Water: Mixes with water in all proportions.
3.3 pH: 1 (100%)
3.4 Initial Boiling Point: 220 deg F
3.5 Specific Gravity: 1.1
______
4.0 FIRE AND EXPLOSION DATA /
______
4.1 Special Fire Hazards: None
4.2 Fire Fighting Methods: Does not support combustion.
______
5.0 REACTIVITY DATA /
______
5.1 Stability: Stable under normal conditions of handling.
5.2 Conditions to Avoid: Mix only with water. Reacts with metals;
reacts vigorously with alkaline chemicals. Do not mix with
chlorinated detergents or sanitizers - will cause hazardous vapors.
______
6.0 SPILL OR LEAK PROCEDURES / USE PROPER PROTECTIVE EQUIPMENT
______
6.1 Cleanup and Disposal: Rinse small amounts to the sanitary sewer
drain with plenty of water; mop up spills and rinse area thoroughly
with water. Consult state/local authorities for limits on chemical
waste disposal.
Product: PHOSPHORIC ACID (REAGENT #071) Page 2 of 2
ECOLAB INC Ecolab Center 071
MEDICAL EMERGENCY ONLY, 24 HOURS SERVICE: 1-800-328-0026
======
7.0 HEALTH HAZARD DATA / DANGER
______
7.1 Effects of Overexposure to Concentrate:
Skin and Eyes: CAUSES SEVERE CHEMICAL BURNS. Eye contact may
______
cause blindness.
If Swallowed: HARMFUL OR FATAL. Causes chemical burns of mouth,
______
throat and stomach.
If Inhaled: Vapors or mist cause irritation, including a burning
______
taste, sneezing, coughing and difficulty breathing. People with
asthma or other lung problems may be more affected.
______
8.0 FIRST AID /
______
8.1 Eyes: Flush at once with cool running water. Remove contact
____
lenses. Continue flushing for at least 15 minutes, holding eyelids
apart so as to rinse entire eye. CALL A PHYSICIAN IMMEDIATELY.
8.2 Skin: Immediately flush skin with plenty of cool running water for
____
at least 15 minutes while removing contaminated clothing and shoes;
discard or wash well before reuse.
8.3 If Swallowed: Rinse mouth at once; then drink 1 or 2 large glasses
______
of water. DO NOT induce vomiting. NEVER give anything by mouth to
an unconscious person.
8.4 If Inhaled: Immediately move to fresh air.
______
IMMEDIATELY CALL THE MEDICAL EMERGENCY NUMBER, 1-800-328-0026,
A POISON CONTROL CENTER OR A PHYSICIAN
______
9.0 PROTECTIVE MEASURES /
______
9.1 Eyes: Wear safety glasses with side shields.
____
Skin: Use any industrial rubber glove.
____
______
10.0 ADDITIONAL INFORMATION/PRECAUTIONS /
______
10.1 Not DOT regulated.
10.2 Purpose of 01/20/98 issue: Add line 1.3
KEEP OUT OF REACH OF CHILDREN
The above information is believed to be correct with respect to the
formula used to manufacture the product. As data, standards and
regulations change, and conditions of use and handling are beyond our
control, NO WARRANTY, EXPRESS OR IMPLIED, IS MADE AS TO THE
COMPLETENESS OR CONTINUING ACCURACY OF THIS INFORMATION.
018 MATERIAL SAFETY DATA SHEET: USA Page 1 of 2
MEDICAL EMERGENCIES ONLY (24 Hour Service): 1-800-328-0026
Medical Calls from Outside of the USA: 1-651-222-5352
Ecolab Inc.
370 N. Wabasha Street, St. Paul MN 55102
Product Information: 1-800-35-CLEAN Issue Date: March 22, 2004
======
1.0 IDENTIFICATION /
1.1 Product Name: POTASSIUM IODIDE - 018
1.2 Product Type: Liquid Test Kit Reagent
1.3 Hazard Rating: Health: 1 Fire: 0 Reactivity: 0
------
Substances Subject to SARA 313 Reporting Are Indicated by "#"
------
2.0 HAZARDOUS COMPONENTS / (in mg/m3)
CAS No. % PEL TWA
2.1 Potassium iodide 7681-11-0 5-20 No No
------
PEL = OSHA 8 hour average in air TWA = ACGIH 8 hour average in air
------
3.0 PHYSICAL DATA /
3.1 Appearance: Clear, colorless liquid; no specific odor
3.2 Solubility in Water: Mixes with water in all proportions
3.3 pH: 9.0 (at 100%)
3.4 Initial Boiling Point: 212 deg F / 100 deg C
3.5 Specific Gravity: 1.000 @ 68 deg F / 20 deg C
------
4.0 FIRE AND EXPLOSION DATA /
4.1 Special Fire Hazards: None, does not support combustion.
4.2 Fire Fighting Methods: Use method appropriate for surrounding fire.
------
5.0 REACTIVITY DATA /
5.1 Stability: Stable under normal conditions of use and handling.
5.2 Conditions to Avoid: Do not mix with other chemicals. Use standard
hygiene practices to maintain product integrity.
------
6.0 SPILL OR LEAK PROCEDURES / WEAR PROPER PROTECTIVE EQUIPMENT
6.1 Cleanup: Dike or dam large spills. Pump to containers or soak up
on inert absorbent. Flush residue or small spills to sanitary sewer.
6.2 Waste Disposal: Consult state/local authority for limits on chemical
waste disposal.
018 Page 2 of 2
Product: POTASSIUM IODIDE - 018
Ecolab Inc.
MEDICAL EMERGENCY ONLY, 24 HOUR SERVICE: 1-800-328-0026
======
7.0 HEALTH HAZARD DATA / CAUTION
7.1 Effects of Overexposure to Concentrate:
Eyes: May cause irritation.
Skin: Prolonged or repeated exposure may cause irritation.
If Swallowed: May cause stomach distress, nausea or vomiting.
------
8.0 FIRST AID /
8.1 Eyes: Flush with cool running water. Remove contact lenses and
flush again for 10-15 minutes.
8.2 Skin: Flush skin with water; wash with soap and water. Remove
and wash contaminated clothing before reuse.
8.3 If Swallowed: Rinse mouth; then drink 1 or 2 large glasses of
water. DO NOT induce vomiting. NEVER give anything by mouth to
an unconscious person.
IF IRRITATION OR DISCOMFORT PERSIST, CALL A PHYSICIAN
------
9.0 PROTECTIVE MEASURES /
9.1 FOR CONCENTRATE:
No protective equipment is necessary under normal use conditions.
Eyes: If splashing may occur, eye protection recommended.
Skin: Wear impervious gloves for prolonged or repeated exposure.
------
10.0 ADDITIONAL INFORMATION /
10.1 Purpose of 3/22/2004 issue: Editorial update. Replaces
January 19, 1998 issue.
10.2 Part Number(s): 56390, 56867
KEEP OUT OF REACH OF CHILDREN
The above information is believed to be correct with respect to the
formula used to manufacture the product in the country of origin. As data,
standards, and regulations change, and conditions of use and handling are
beyond our control, NO WARRANTY, EXPRESS OR IMPLIED, IS MADE AS TO THE
COMPLETENESS OR CONTINUING ACCURACY OF THIS INFORMATION.
038 MATERIAL SAFETY DATA SHEET: USA Page 1 of 2
MEDICAL EMERGENCIES ONLY (24 Hour Service): 1-800-328-0026
Medical Calls from Outside of the USA: 1-651-222-5352
Ecolab Inc.
370 N. Wabasha Street, St. Paul MN 55102
Product Information: 1-800-35-CLEAN Issue Date: March 26, 2004
======
1.0 IDENTIFICATION /
1.1 Product Name: STARCH INDICATOR - 038
1.2 Product Type: Liquid Test Kit Reagent
1.3 Hazard Rating: Health: 1 Fire: 0 Reactivity: 0
------
Substances Subject to SARA 313 Reporting Are Indicated by "#"
------
2.0 HAZARDOUS COMPONENTS /
2.1 This product is not considered hazardous according to the criteria
of 29 CFR 1910.1200. It does not contain 1% or more of any substance
listed in SARA 313. It is not a DOT hazardous material.
------
3.0 PHYSICAL DATA /
3.1 Appearance: Clear, colorless liquid; no specific odor
3.2 Solubility in Water: Mixes with water in all proportions
3.3 pH: 7 (at 100%)
3.4 Initial Boiling Point: 212 deg F / 100 deg C
3.5 Specific Gravity: 1.000 @ 68 deg F / 20 deg C
------
4.0 FIRE AND EXPLOSION DATA /
4.1 Special Fire Hazards: None, does not support combustion.
4.2 Fire Fighting Methods: Use method appropriate for surrounding fire.
------
5.0 REACTIVITY DATA /
5.1 Stability: Stable under normal conditions of use and handling.
5.2 Conditions to Avoid: Do not mix with other chemicals. Use standard
hygiene practices to maintain product integrity.
------
6.0 SPILL OR LEAK PROCEDURES / WEAR PROPER PROTECTIVE EQUIPMENT
6.1 Cleanup and Disposal: Rinse small amounts to the sanitary sewer
drain with plenty of water; mop up spills and rinse area thoroughly
with water.
038 Page 2 of 2
Product: STARCH INDICATOR - 038
Ecolab Inc.
MEDICAL EMERGENCY ONLY, 24 HOUR SERVICE: 1-800-328-0026
======
7.0 HEALTH HAZARD DATA / CAUTION
7.1 Effects of Overexposure to Concentrate:
Eyes: May cause irritation.
Skin: Prolonged or repeated exposure may cause irritation.
If Swallowed: No effects anticipated, but may cause stomach upset.
------
8.0 FIRST AID /
8.1 Eyes: Flush with cool running water. Remove contact lenses and
flush again for 10-15 minutes.
8.2 Skin: Flush skin with water; wash with soap and water. Remove
and wash contaminated clothing before reuse.
8.3 If Swallowed: Rinse mouth; then drink 1 or 2 large glasses of
water. DO NOT induce vomiting. NEVER give anything by mouth to
an unconscious person.
IF IRRITATION OR DISCOMFORT PERSISTS, CALL A PHYSICIAN
------
9.0 PROTECTIVE MEASURES /
9.1 FOR CONCENTRATE:
No protective equipment is necessary under normal use conditions.
------
10.0 ADDITIONAL INFORMATION /
10.1 Purpose of 3/26/2004 issue: Editorial update.
Replaces January 19, 1998 issue.
10.2 Part Number(s): 56408, 56869
KEEP OUT OF REACH OF CHILDREN
The above information is believed to be correct with respect to the
formula used to manufacture the product in the country of origin. As data,
standards, and regulations change, and conditions of use and handling are
beyond our control, NO WARRANTY, EXPRESS OR IMPLIED, IS MADE AS TO THE
COMPLETENESS OR CONTINUING ACCURACY OF THIS INFORMATION.
069 *MATERIAL SAFETY DATA SHEET* Page 1 of 2
______
MEDICAL EMERGENCY ONLY, 24 HOURS SERVICE: 1-800-328-0026
ECOLAB INC Ecolab Center Product Information: 1-612-293-2233
St. Paul MN 55102 Date of Issue: January 20, 1998
======
1.0 IDENTIFICATION /
______
1.1 Product Name: SODIUM THIOSULFATE N/20 (REAGENT #069)
1.2 Product Type: Test Kit Reagent
1.3 Hazard Rating: Health - 0 Fire - 0 Reactivity - 0
_ _ _
______
2.0 HAZARDOUS COMPONENTS /
______
2.1 This product is not considered hazardous according to the criteria
of 29 CFR 1910.1200. It does not contain any substance listed in
SARA 313. It is not a DOT hazardous material.
______
3.0 PHYSICAL DATA /
______
3.1 Appearance: Clear, odorless liquid
3.2 Solubility in Water: Mixes with water in all proportions.
3.3 pH: 6 (100%)
3.4 Initial Boiling Point: 212 deg F
3.5 Specific Gravity: 1
______
4.0 FIRE AND EXPLOSION DATA /
______
4.1 Special Fire Hazards: None
4.2 Fire Fighting Methods: Does not support combustion.
______
5.0 REACTIVITY DATA /
______
5.1 Stability: Stable under normal conditions of handling.
5.2 Conditions to Avoid: No special requirements; use standard
industrial practices
______
6.0 SPILL OR LEAK PROCEDURES / USE PROPER PROTECTIVE EQUIPMENT
______
6.1 Cleanup and Disposal: Rinse small amounts to the sanitary sewer
drain with plenty of water; mop up spills and rinse area thoroughly
with water. Large spills should be well diluted with water before
sewering. Consult state/local authorities for limits on chemical
waste disposal.
Product: SODIUM THIOSULFATE N/20 (REAGENT #069) Page 2 of 2
ECOLAB INC Ecolab Center 069
MEDICAL EMERGENCY ONLY, 24 HOURS SERVICE: 1-800-328-0026
======
7.0 HEALTH HAZARD DATA / CAUTION
______
7.1 Effects of Overexposure to Concentrate:
Skin and Eyes: May cause minor irritation.
______
If Swallowed: May cause stomach distress, nausea or vomiting.
______
______
8.0 FIRST AID /
______
8.1 Eyes: Flush immediately with cool running water. Remove contact
____
lenses, if used, and then flush again.
8.2 Skin: Flush skin with water, then wash with soap and water.
____
Remove contaminated clothing and wash before reuse.
8.3 If Swallowed: Rinse mouth; then drink 1 or 2 large glasses of
______
water. DO NOT induce vomiting. Never give anything by mouth to an
unconscious person.
IF IRRITATION OR DISCOMFORT PERSISTS, CALL A PHYSICIAN.
______
9.0 PROTECTIVE MEASURES /
______
9.1 No requirements beyond standard industrial hygiene practices.
______
10.0 ADDITIONAL INFORMATION/PRECAUTIONS /
______
10.1 Not DOT regulated.
10.2 Purpose of 01/20/98 issue: Review; editorial changes
KEEP OUT OF REACH OF CHILDREN
The above information is believed to be correct with respect to the
formula used to manufacture the product. As data, standards and
regulations change, and conditions of use and handling are beyond our
control, NO WARRANTY, EXPRESS OR IMPLIED, IS MADE AS TO THE
COMPLETENESS OR CONTINUING ACCURACY OF THIS INFORMATION.
070 *MATERIAL SAFETY DATA SHEET* Page 1 of 2
______
MEDICAL EMERGENCY ONLY, 24 HOURS SERVICE: 1-800-328-0026
ECOLAB INC Ecolab Center Product Information: 1-612-293-2233
St. Paul MN 55102 Date of Issue: January 20, 1998
======
1.0 IDENTIFICATION /
______
1.1 Product Name: SODIUM THIOSULFATE N/200 (REAGENT #070)
1.2 Product Type: Test Kit Reagent
1.3 Hazard Rating: Health - 0 Fire - 0 Reactivity - 0
_ _ _
______
2.0 HAZARDOUS COMPONENTS /
______
2.1 This product is not considered hazardous according to the criteria
of 29 CFR 1910.1200. It does not contain any substance listed in
SARA 313. It is not a DOT hazardous material.
______
3.0 PHYSICAL DATA /
______
3.1 Appearance: Clear, odorless liquid
3.2 Solubility in Water: Mixes with water in all proportions.
3.3 pH: 6 (100%)
3.4 Initial Boiling Point: 212 deg F
3.5 Specific Gravity: 1
______
4.0 FIRE AND EXPLOSION DATA /
______
4.1 Special Fire Hazards: None
4.2 Fire Fighting Methods: Does not support combustion.
______
5.0 REACTIVITY DATA /
______
5.1 Stability: Stable under normal conditions of handling.
5.2 Conditions to Avoid: No special requirements; use standard
industrial practices
______
6.0 SPILL OR LEAK PROCEDURES / USE PROPER PROTECTIVE EQUIPMENT
______
6.1 Cleanup and Disposal: Rinse small amounts to the sanitary sewer
drain with plenty of water; mop up spills and rinse area thoroughly