Instruction of use

1.Set button

The product uses the touch screen mode, through conversational picture so that customers are easy to use and design of constant temperature and humidity of programmable controller

2. Set value input keyboard

Note: if the error in the input data will be displayed in the keyboard ( INPUT ERR input error )

①Digital input keys ②DI name input key

2.1 Set value input key function and description

①Labeled" setting range.

②Labeled" operation of the events".

③"The setting that the window" exceeds the set range, will be labeled error ( error ).

④Repair charge input value when using word removal, input value.

⑤Stop input to return to the main screen when using.

⑥Save input values to return to the main screen.

⑦Clear input value when using.

⑧Input decimal point using.

⑨Input symbol ( + / -)

2.2Parameter setting method

Example : 50setting value for - 13.57( constant ) method is as follows:

→In the picture on the set value by the key input.

→In turn input(①→②→③→④→⑤→⑥→⑦)

3.Monitor screen

The controller to start the screen, accessible from the main screen to enter other picture or view system information.

4.Monitor screen

Monitor screen flow chart, divided into three parts: please look carefully

4.1 Monitor stop scree

① ② ③④

The monitor screen click Run, pop-up dialogs:As shown above: rerun refers to the running time to start;

Continue to run namely : continuing the last run time start time

Cancel cancel operation:

In the surveillance operation picture click switch appear as shown in Figure 11picture:

T-AT: said test room temperature PID automatic calculation,When the background is red, for automatically setting status, When the temperature fluctuations cannot be stable,Can automatically calculate operation;

S-AT: saturated barrel temperature PID automatic calculation

4.2 Monitor the operation screen

4.3 Monitor output screen

Output: display of temperature or humidity or salt fog output value.

Spray: spray mode, selectable continuous, periodic and continuous three working modes

Spray timing: statistical spray work time

Effective time: test chamber temperature and saturated the barrel temperature to reach the standby operating within the valid time;

Running time: from the beginning to run to the end of the time

In Figure 10, click the toggle appear shown on the left picture

To set the temperature and salt fog PID self-tuning;

Click the arrow to switch back to the surveillance footage


5 . Operation set screen

Serial number / Command / Explain / Remarks
① / Type of test / Click to enter the test categories setting picture / See the test class picture comments
② / Standby set / Click to enter the standby setting picture / In the standby set picture comments
③ / Cumulative time / Click to enter the cumulative time setting picture / See the cumulative time setting picture comments
④ / Basic setting / The basic setup screen / In basic setting
⑤ / Spray pattern / Click into the spray means setting interface / In the spray mode setting picture definition
⑥ / Alarm record / Click into the alarm record screen / See alarm record picture comments

5.1type of test pictures

Test type: salt spray test, corrosion test; run stop click can choose, when the background color to green for the selected state

Test chamber temperature : shows the current temperature test chamber;

Saturation temperature: current temperature saturated barrel barrel

Test time: experimental runs in real time

Note: click on the double arrow to return to operation set menu

5.2standby setting screen.

Standby set: set standby moves on and off

Test room area: setting a standby operation test chamber temperature range

Saturated barrel area: setting a standby operation saturated barrel temperature range

Standby time: set the test temperature or saturation temperature standby operation of standby time; ( when the test temperature or saturation temperature of the current display values within a set time can not reach the set value, the contact standby )

5.3. Cumulative time picture

Test total time: statistical experimental operation of the accumulative total time

Spray cumulative time: statistical spray test run time

5.4. Basic setting:

Blackout: stop and continue, continue namely continued last power-down state continue to run;

Lock for locking the closure: OFF, ON to start locking, starting

State parameter modification is not available, but can switch the interface. If there is not the issue of parameter modification. You can view the locked state is ON.

Backlight time: backlight brightness time length,0Chang Liang said backlight backlight.

Automatic defrosting time: automatic fog when the running time. According to the setting, to certain conditions when the automatic defrosting and defogging, set the length of time.

5.5. The spray pattern picture:

Working mode: continuous, periodic, manual, three kinds of work modes

Continuous spraying time: performs continuous spray work time, click on the yellow area setting.

Delay: Click to run when the first delay long to run.

Time: operation run length.

Closing time: run stop after stop time length.

Cycles: cycle time cycle times.

5.6:Alarm record screen:

6. Preset picture

Preset time

▶设置当

Serial number / Command / Explain / Remarks
① / Date adjustment / Set current time
( year, month, day, time, branch )
② / Appointment time / To set an appointment time
( year, month, day, time, branch )
③ / Reservation set / Preset state open
( ON ) or closed ( OFF ) / Not to set an appointment time can not be opened, after the opening, see Figure 10

7. Display set

Set screen brightness, softness, automatic calculation key display and hide.