CURRICULAM VITAE
KARTIK GULIPALLI,Contact Number: 0091-8341367237,9059683173
Email:
Career Objective:Seeking a rewarding and challenging career with opportunities for future growth and development with the organization, where my knowledge, abilities & skills are optimized and my experience is channeled towards the success of the organization.
Profile:
- 3+ years experience in inspection quality control and Non Destructive Testing of Pressure vessel, Heat–exchangers, piping and structures for petro chemical plants, Shipyards, gas plants & power plants fabrication.
- Capable in supervising & monitoring and also having extensive experience in carrying out independently below NDT methods.
- Capable of interpreting test result to various standards.
- Visual inspection and NDT controlling as per codes and specification requirements
- Carried out Ultrasonic Testing and interpretation as per relevant code
- B.Tech(C.S.E) from University of JNTU Kakinada, In Chaitanya Engineering college, Visakhapatnam in 2012.
- Intermediate from A.P Board of Intermediate Education (M.P.C), A.N.R College, Gudivada. In 2008.
- S.S.C from A.P Board of School of Secondary education in Z.P.H School ,Vanapamula. In 2005.
BARC Level -2 in
- Radiography Testing
- Radiography Testing
- Ultrasonic Testing
- Magnetic Particle Testing
- Penetrant Testing
- Ms-word, Ms-Excel, Ms-Power Point
- C,C++,JAVA, Oracle, HTML
Period :September2013 to Till date
Employer:M/s.GALAXY NDT INSPECTIONS
Location : Visakhapatnam, Andhrapradesh, INDIA
Position:Radiological Safety Officer (Site Incharge) and NDT Coordinator
Period :July 2012 to August 2013.
Employer:M/s.MARINE INFRE
Location : Visakhapatnam, Andhrapradesh, INDIA
Position:NDT-Coordinator and Multi-Technician
DUTIES AND RESPONSIBILITIES:
- Responsible to effectively communicate the NDT status, general welding performance and the NDT subcontractor's performance.
- Establishes field inspection and testing procedures for fabrication, welding and piping.
- Establishes and maintains fabrication and welding records.
- Supervises inspection and test ensuring reporting and records compilation in line with project requirements.
- Liaises with section/ site engineers to clarify the requirements and criteria for inspection and test for the works.
- Liaises with contractor's representative for field inspection and test schedule.
- Schedules inspection and test on a daily basis coordinating "hold point" witnessing by contractor/ third party.
- Report all non-conformances to the Quality Manager.
- Checks NDT reports and establishes welding repair requirements.
- Liaises with QC engineer with regard to welding procedures and qualifications.
- Ensure the welding is carried in accordance with the approved welding procedures.
- Carried out ultrasonic thickness measurement of pipe lines, equipments, corrosion check on the pressure vessels, tanks, exchangers, column, filters etc. Lamination checking on the new raw materials.
- Good experience in film processing and interpretation of films for weld defect
- Carried out Penetrant Inspection on weld joints equipments, components such as extension bellows, pump, casing, shaft etc in removable, water washable and fluorescent methods.
- Pressure vessel attachment welds etc.
- Magnetic Particle inspection for machinery components, tank nozzles, impellers.
- Interpretation of films for weld defect and Good experience in film processing
- Carried out all NDT Inspection of Shaft and various types of welds of Submarines at M/s. NAVAL DOCKYARD, VISAKHAPATNAM (A.P).
- Carried out all Radiography Inspection of various types of Structural, Pipe lines and Shipping at M/s. HINDUSTAN SHIPYARD LIMITED, Visakhapatnam (A.P).
- Carried out all NDT of Boiler Tubes at M/s. POWER MECH PROJECTS at M/s. N.T.P.C Visakhapatnam (A.P).
- Carried out all NDT of Pipe Lines, Plates and Vessels at M/s. FLASH FORGE PROJECTS PVT LTD at VISAKHAPATAM.
- Carried out all NDT Inspection of Pipe lines and Structural at M/s. POWER MECH PROJECT at M/s. MADHUCON PROJECTS LTD at Nellore (A.P).8
- Site In charge at M/s. POWER MECH PROJECT at M/s. T.P.C.I.L at Nellore (A.P).
- Site In charge at M/s. Nagarjuna Constructions Company Ltd at Jagadalpur ( Chhattisgarh ).
- Site In charge at M/s. BRIDGE AND ROOF LTD at Visakhapatnam(Andhrapradesh).
I Ultrasonic:
Modsonic
Ultrasonic Flaw Detector—DGS
IIRadiography:
Techops 660 Model
ROLI 1,2&3
Delta
X-Ray Digi Dog.,
III Magnetic Particle (Dry, Wet, Fluorescent & Visible):
Electronic Magnetic Yoke
Permanent Magnet
IV Positive Material Identification :
Brooker Alloys Analizer
V Hardness Testing :
YAMMAYO Bliss
MH-310
ACHIEVEMENTS:
- Get tenniquite center john winners.
- High jump Dist. Second.
- Member of NCC got a silver ranking.
Pass Port Number / Date of Issue / Date of expiry
Z2742079 / 04-11-2013 / 03-11-2023
PERSONAL DETAILS:
Name : G.Kartik
Father’s Name : G.Srinivasa Rao
Date of Birth : 20-08-1990
Sex : Male
Marital Status : Married
Nationality : Indian
Languages Known : Telugu, English & Hindi
Hobbies : Playing Cricket, Chess.
Declaration:
I hereby declare that the information furnished by me in this application is true, complete and correct to the best of my knowledge and belief.
Place: Your’s Truly
Date: (G.KARTIK)