SECTION 09810
ACOUSTICAL SPACE UNITS
SOUND DIFFUSERS
PART 1 GENERAL
1.01 SUMMARY
- Section Includes: Custom fabricated Sound Diffusers.
1.02 REFERENCES
- ASTM International:
- ASTM C423 Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method.
- ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials.
- ASTM E795 Standard Practices for Mounting Test Specimens During Sound Absorption Tests.
1.03 SYSTEM DESCRIPTION
- Performance Requirements:
- Surface Burning Characteristics (ASTM E84): Wall & Ceiling mounted Model Geometric Sound Diffusers shall be Class A rated, minimum.
1.04 SUBMITTALS
- General: Submit listed submittals in accordance with Conditions of the Contract and Division 1 Submittal Procedures Section.
- Product Data: Submit product data sheet, for specified products.
- Shop Drawings: Submit shop drawings showing layout, edge profiles and panel components, including anchorage, accessories, finish colors and textures.
1.05 DELIVERY, STORAGE & HANDLING
- General: Comply with Division 1 Product Requirements Section.
- Delivery: Deliver materials in manufacturer’s original, unopened, undamaged containers with identification labels intact.
- Storage and Protection: Store materials protected from exposure to harmful environmental conditions and at temperature and humidity conditions. Environmental conditions required for storage are the same as for installation, see 1.07 – A, Project Conditions.
1.06 PROJECT CONDITIONS
- Environmental Requirements: Do not install diffusers or reflectors until wet work, such as concrete and plastering, is complete; the building is enclosed; and the temperature and relative humidity are stabilized at 60 - 80 degrees F (16 - 27 degrees C) and 40% to 50%, respectively.
PART 2 PRODUCTS
2.01 ACOUSTICAL DIFFUSERS
- Manufacturer: Kinetics Noise Control.
- Contact: PO Box 655, 6300 Irelan Place, Dublin, OH 43017; Telephone: (614) 889-0480; Fax: (614) 889-0075; E-mail: ; Web site: www.kineticsnoise.com.
- Substitutions: No substitutions permitted.
2.02 MANUFACTURED UNITS
- Geometric Sound Diffuser Panel, Thermo-molded:
- Constructed from 0.125 inch (3.2 mm) thermo-molded co-polymer.
- Sizes and shapes as indicated on the drawings.
Select from:
Specifier Note: Width and length dimensions are nominal. Actual width and length dimensions on all Geometric Diffusers except the 4 ft. x 6 ft. size are ¼ inch less than nominal dimensions stated. These Diffusers are designed for installation in a standard 15/16 in. lay-in ceiling grid or for wall mounting.
- 2 x 2 ft. x 5.25 inches (610 x 610 x 133 mm) radiused
- 2 x 2 ft. x 6.75 inches (610 x 610 x 171 mm) offset pyramidal
- 2 x 4 ft. x 5.25 inches (610 x 1220 x 133 mm) radiused
- 2 x 4 ft. x 6.75 inches (610 x 1220 x 171 mm) offset pyramidal
- 3 x 3 ft. x 7.00 inches (915 x 915 x 178 mm) radiused
- 3 x 4 ft. x 9.75 inches (915 x 1220 x 248 mm) radiused
- 3 x 6 ft. x 9.75 inches (915 x 1830 x 248 mm) radiused
- 4 x 4 ft. x 9.75 inches (1220 x 1220 x 248 mm) radiused
4 x 4 ft. x 9.75 inches (1220 x 1220 x 248 mm) offset pyramidal
- 4 x 6 ft. x 9.75 inches (1220 x 1830 x 248 mm) radiused
- Edge Detail: Rounded pencil edge thermo-molded frame formed on a geometric radiused or offset pyramidal shaped unit.
- Finish: [Standard white textured finish] [Fabric facing: Manufacturer’s standard 100 percent polyester woven fabric, FR701 Style 2100 by Guilford of Maine]
a. Color: As selected from manufacturer’s full range of colors.
- Sound Absorption (ASTM C423): Noise Reduction Coefficient shall be no greater than .10 for A Mounting and E400 (lay-in ceiling) Mounting.
- Mounting: [Wall mount with top of panel angle and Z-Clip. Optional: Bottom angle if required to secure panel] [Ceiling mount; lay-in 15/16-inch (24 mm) grid]
PART 3 EXECUTION
Specifier Note: Paragraph below is an addition to CSI SectionFormat and a supplement to this specification. Retain or delete paragraph below per project requirements and specifier’s practice.
3.01 MANUFACTURER’S INSTRUCTIONS
- Compliance: Comply with manufacturer’s product data, including product technical bulletins, product catalog installation instructions and product carton instructions for installation.
3.02 EXAMINATION
- Site Verification of Conditions: Verify that substrate or supporting structure, which has been previously installed under other sections, is acceptable for product installation in accordance with manufacturer’s instructions.
3.03 CLEANING
- Follow manufacturer’s instructions for cleaning panels soiled during installation. Replace panels that cannot be cleaned to as new condition.
- Keep site free from accumulation of waste and debris.
END OF SECTION