RTTUZYUW RHSSXYZ0001 0951139-UUUU--RHSSSUU.
ZNR UUUUU
R 051146Z APR 05
FM OU:TACOM-RI,OU:TACOM-RI SFTY OFC(UC)
TO CG ARLINGTON SMDC
CG TRADOC
CID001 HQ BELVOIR
COMMAND GROUP
INSCOM CG
LCC ALEXANDRIA
MDW CDR FT MCNAIR DC
MEDCOM CMD GEN
MSG CEN HQ USACE
OPSDIR WEST POINT USMA
USAREUR CG
USARPAC CG
USASOC SAFETY DIR
YPG CDR
21 TSC EOC
AASA
C-130 OMC CAIRO EG
CDR ANAD
EOC OFCR
HQ 200 MMC
HQ 21 TSC
NETCOM COMMAND GROUP
NGB WASHINGTON DC
SAFETY
SOH
USAMC CEGA CDR
USAMRMC CDR
USARC DCS G3
USARPAC G4 DCSLOG
WSMR CG
TRADOC DOL G4
AL 12285
APG DTC CDR1
ARDEC EOC
CMC WASHINGTON DC SD
EOD TECHDET
HQ IMA NW REGION OFFICE
JMC MCLNO
JMC TRANS OFC
LCC BUCHANAN
MSG CEN ERDC MS
PEO CSS
SEG
TACOM-RI SFTY OFC
INFO USASC RUCKER
ARMY SAFETY OFC
CDR LOGSA
CG MARCORSYSCOM 00T
CHIEF OF ENGINEERS
COMNAVSAFECEN NORFOLK VA
COMNAVSPECWARCOM CORONADO CA
DCS G3
DCS G4
HQ AFSC
IG
INSPECTOR GENERAL
JMC NICP
MONMOUTH SAFETY DIR
NAVSPECWAROPSUPPTEAM ONE CORONADO CA
OPS
SUP MAINT
SURGEON GENERAL
TACOM SAFETYOFUSE
BT
UNCLAS
UNCLAS
SUBJECT: Ground Precautionary Message (GPM) TACOM Control No. GPM 05
-007, Power Cable Assembly, NSN 6150-00-255-8332
**************************************************
* ATTENTION *
* THIS MESSAGE CONTAINS INFORMATION THAT IS *
* VITAL TO THE SAFETY OF ARMY PERSONNEL *
* OPERATION OR MAINTENANCE OF ARMY EQUIPMENT *
**************************************************
References:
1. Distribution: Note this is a "Ground Precautionary Message
". MACOM Commanders will immediately retransmit this message to all
subordinate commands
/activities within 24 hours of receipt of this message and acknowledg
e receipt of this message within five working days to Safety Office,
Tank-automotive and Armament Command-Rock Island (TACOM-RI), AMSTA-CS
-CZR, Rock Island, IL 61299-7630, e-mail: .
2. Problem Discussion:
a. Summary Of Problem. Two power cables supplied by Porter Manu
facturing were reported defective by a user at Eglin Air Force Base.
The cables were confirmed defective by TACOM
-Rock Island engineering, safety, and quality assurance personnel. T
hese defects could possibly cause damage to equipment and
/or injury to personnel. There are no reported problems with power c
able assemblies from other manufacturers. The following problems wer
e discovered:
(1) On one cable, on the male connector end the "C" phase pin
has been placed in the Neutral pin
's location and the Neutral pin has been placed in the "C" phase pin
's location.
(2) On the second cable, on the female connector end, the "C"
phase wire has been connected to the Neutral conductor and the Neutr
al wire has been connected to the "C" phase conductor.
b. Parts, Assembly, Or Components To Be Inspected. Power cable
assembly, NSN 6150-00-255-8332, P/N 72289-100, 120
/208V, 3 phase, 60 HZ, 60 amp, manufactured by Porter Manufacturer, C
AGE 0BGA6.
3. User Actions: The following procedures apply only to Porter cable
s NSN 6150-00-255
-8332. There are no reported problems with power cable assemblies fr
om other manufacturers.
a. Task Or Inspection Suspense Date. Inspection shall be perfor
med within five working days of receipt of this message or prior to p
lacing any Porter Cable Assembly into service, whichever event occurs
first.
b. Reporting Compliance Suspense Date. Report findings of any de
fective power cable assembly within five working days using the Army
Electronic Product Support (AEPS)
/Electronic Deficiency Reporting System (EDRS).
c. Inspection Procedures. Inspect all on
-hand power cable assemblies supplied by Porter Manufacturing in curr
ent use or in warehouse stock. Power cable assemblies supplied by Po
rter Manufacturing can be identified by the code 0BGA6 located on a y
ellow band on both ends of each power cable assembly.
(1) To test for the conditions reported in paragraph 3a
(1) and 3a
(2) above, you will need a multimeter in continuity mode. A multimete
r is available in the General Mechanic's Tool Kit, NSN 5180-01-481
-8389, 5180-01-483-0250 and 5180-01-483-0249, and the Multi
-Capable Maintainer Tool Kit, NSN 5180-01-493-1664 and 5180-01-493
-1665.
(2) Each power cable assembly must be tested individually and
not while connected to any additional power cable assemblies. Touch
one lead of the multimeter to the A phase pin of the cable assembly.
The phases are identified by raised letters inside of the connectors
. Touch the other multimeter lead to the A phase socket on the other
end of the cable assembly. The multimeter should indicate continuit
y. Repeat this test for phases B and C, the Neutral, and the Ground,
in turn.
d. Tag as defective, isolate and report any cable that does not
have A - A, B - B, C - C, N - N or G - G continuity. Report defectiv
e power cable assemblies via a SF
-368 Quality Deficiency Report. This can be done via the AEPS
/EDRS web site at: by emailing to: QAWQDRS
@RIA.ARMY
.MIL or if unable to use either of these methods by fax to commercial
(309) 782-6653, DSN 793
-6653 and confirmation at commercial (309) 782-7698, DSN 793
-7698. Power cable assemblies, which are tested and are not defectiv
e, may be returned to service or stock with no restrictions.
4. TACOM/PM Actions:
a. Actions are underway to screen all depot stock of Porter Manu
facturing supplied power cable assemblies.
b. At request of TACOM, Porter Manufacturing reviewed inspection
procedures and implemented two changes: 1) in addition to the cable
assembler a second person must now check the wiring color codes befor
e the connector shell is closed, and 2) a new continuity tester was m
ade which eliminates human error and also assures correct placement o
f the long pin (Neutral) and short pins (A, B, C phases) in the conne
ctor.
5. Supply Status:
a. Requisitioning Instructions. Replacement cable
(s) will be shipped upon receipt of defective Porter cable(s).
b. Disposition. Disposition instructions for defective power ca
ble assemblies will be provided in response to SF-368.
6. Points of Contact:
a. TACOM POC is Kathy Carlson, AMSTA-LC-CTME, DSN 793
-5074, commercial (309) 782-5074, email:
.mil or
Randy Lange, AMSTA-LC-CTME, DSN 793-3160, commercial (309)782
-3160, email: .
b. Technical POC: Dale Holland, AMSRD-AAR-AIL-TC, DSN 793
-8146, commercial (309) 782-8146, email:
.mil or Dave Myers, AMSRD-AAR-QEP-C, DSN 793-6705, commercial (309
)782-6705, email: .
c. Safety Engineering POC: Gavin Ziegler, AMSTA-CS-CZR, DSN 793
-2995, commercial (309) 782-2995, email:
d. To find your TACOM Logistics Assistance Representative (LAR
), you must be a registered user in the Army Electronic Product Suppo
rt (AEPS) database, click on this link:
/Services/Lars/Tacom/larmap/LARlocate/larmap
.cfm. Then select the appropriate region, i
.e. CONUS, USAREUR, Far East, Kuwait. Select the location nearest yo
u and click on a name. This will give you a LAR
's name, DSN and commercial phone number, email address, and photo.
If you are not a registered user, request access at the public page:
.cfm, click on "Access Request Form" and follow the instructions for
obtaining an AEPS userid. If you don
't have access to AEPS, you can also obtain this information by conta
cting the TACOM Senior Command Representative (SCR) for your area.
CONUS
-East (includes all units east of the Mississippi, FORSCOM, and all N
ational Guard and Reserve units), DSN 236-6951, Commercial 910-396
-6951.
CONUS
-Central (includes all units in North Dakota, South Dakota, Minnesota
, Nebraska, Iowa, Missouri, Kansas, Oklahoma, Arkansas, Louisiana, Te
xas, Colorado, New Mexico, and all National Guard and Reserve units
), DSN 737-0263, Commercial 254-287-0263.
CONUS
-West (includes all units in Washington, Oregon, Nevada, California,
Arizona, Utah, Idaho, Montana, Wyoming, and all National Guard and Re
serve units), DSN 357-2991, Commercial 253-967-2991.
USAREUR (Great Britain, Germany, Belgium, Luxemburg, Italy, Bosnia,
Kosovo, and Macedonia) DSN 314-375-3461, Commercial 01149 621-487
-3461, in Germany, 0621-487-3461.
Far East (includes Alaska, Hawaii, Korea, Okinawa, Kwajlein, and Ja
pan) DSN 315-722-3552, commercial 011 82 32 520-6552.