MSD P11207Test Plan1/5/11
Test T5: Power Consumption of the module
Objective
Engineering Specs Tested: ES7
This test will measure the current consumption of the module.
Equipment Required
2 laptop computers running Windows
2 copies of TI SmartRF Studio software
2 copies of TI SmartRF Flash Programmer
2 USB cables (Type A to Type B)
2 TI CC Debuggers
2 Mid-Range RF modules
1 External Power Supply
1 Oscilloscope
1 Oscilloscope Probe
Prototype board
Resistor 10Ω
Location
EE Lab
Procedure:
Figure 1: Measurement Setup
The current consumption varies rapidly and to estimate the maximal current consumption, the current is measured with an oscilloscope voltage probe over a 10Ω resistor in series with the power supply. The use of the resistor and oscilloscope allows measurement of the current consumption as a function of time, and is therefore necessary to calculate battery life time.
This method also gives a visual representation of the current consumption during active and sleep mode of the device.
Note: This measurement method may influence the result because of the voltage drop over the resistor and the stray (cable) resistance. Ideally the measurement setup should have been verified with a high precision amperemeter. However the accuracy will be defined by other factors and a higher accuracy here would not affect the final results. The results are also read manually from the oscilloscope, which will also influence on the accuracy.
Note: All the files needed during this procedure can be found on the Edge website of Project 11207, under MSD II/Test Plan/ Test Plan Files
- Place laptops 5 meters apart on a table, with a clear line of sight
- Configure the power supply to provide 3.3V with a minimum current of 500mA. Don’t turn it on yet.
- Create the circuit corresponding to the schematic in figure 1 and connectmodule A to the power supplyand the oscilloscope as indicated.
- Connect module A to laptop A using the CC Debugger (for data communication)
- Turn on the Power supply
- Connect module B to laptop B using the USB cable (for power supply)
- Connect also module B to laptop B via CC Debugger (for data communication)
- On both computers, run TI Smart RF Flash Programmer:
- In the System on Chip Window, select your device, which should have the Chip Type CC1111
- In the section Flash image, Select the file “Power_Test.hex”
- In the section actions, select “Erase, Program and Verify”
- Click on “Perform actions”
- Close Flash Programmer
- Repeat with the second module
- Power on laptop “A” (Transmitter), and run Texas Instruments SmartRF Studio 7 software.
Figure 2: Smart RF Studio First Window
- Select CC1111
Figure 3: Smart RF Studio TX Window
- In the new window, Select “Expert Mode”
- Select the Field “Packet TX” in the bottom of the window
- Open file configuration “Power_TX_Configuration.srfs” (File/Open Cfg)
- Power on laptop “B” (Receiver), and run also Texas Instruments Smart RF Studio.
- Select CC1111
- In the new window, Select “Expert Mode”
- Select the Field “Packet TX” in the bottom of the window
- Open file configuration “Power_RX_Configuration.srfs” (File/Open Cfg)
Figure 4: Smart RF Studio RX Window
- Click on the Start Button
- On laptop “A” start the transmission of the packets by clicking on the button “Start”
Figure 5: Start Button
- Record the power consumption during transmission on the oscilloscope
- Zoom on one of the sequence during which the transceiver is sending a packet and record the maximum value of current
- Record the exact value of the voltage
- Calculate the maximum power consumption and record it.
- Repeat Steps 1 to 15 with Module A as the receiver (Open “Power_RX_Configuration.srfs”) and module B as the transceiver (Open “Power_TX_Configuration.srfs”) to calculate the maximum power consumption during the reception.
Results
Date: _____1/28/11______Engineer Initials: ___RT______
Pass / Fail Criteria: Power consumption less than 5W
Measured Power Voltage during transmission: ____3.7V______
Maximum Measured Current Consumption during transmission:____27.45mA______
Maximum Power Consumption during transmission: _____102mW______Result: Pass / Fail
Measured Power Voltage during reception: ______3.7V______
Maximum Measured Current Consumption during reception:____26.25mA______
Maximum Power Consumption during reception: _____97mW______Result: Pass / Fail