JESSIE D. PALMA

E-mail add:

Mobile #: +97433169541 (Qatar)

+639281462929 (Philippines)

CURRENT POSITION: ElectricalInstrumentInspector

WORK EXPERIENCE SUMMARY

I have 12 years + 5 months extensive experience in the field of electrical maintenance, start-up & commissioning, installation & erection, and testing & inspection. In addition, I have been working in instrumentation for 4 years and good understanding in mechanical works either maintenance or installation.I’m currently working in Stanley ConsultantsInc, Doha Qatar as Electrical & Instrument Inspector for Pumping Station 70 & Pumping Mains – Doha North Sewerage Treatment Plant (monitored & controlled via SCADA). I have been assigned to look at all matters related to quality assurance of electrical & instrumentation works. Perform final inspections (RFIA – Request For Inspection & Approval) and draft NCR if there is non-compliance and submit to Resident Engineer. Review electrical & instrumentation contractor submittals and forward comments to Senior Electrical Engineer. Prepare worksheets for electrical & instrumentation monthly progress and submit to Senior Schedule Planner and Quantity Surveyor. Prepare daily project report.Carry outmonthly electrical safety inspection and make a report.

I started to explore my career in the Middle East since September 2003, my first job in GCC was in Saudi Arabia and I worked as Senior Electrical Technician, start-up & commissioning, and maintenance in Chemical Process Plant. For almost 6 years in Chemical Process Plant I have been exposed to various complex fault findings and preventive maintenance to different kind of equipments up to voltage rating of 34.5kV. Understand well the control process and maintenance of Gas-Insulated Switchgears (SF6), Air-Insulated Switchgears, Metalclad Switchgears, Oil-filled Power Transformers, Dry-type transformers, 4.16kV & 480V motor control units, Distributed Control System (DCS) by YOKOGAWA version Centum CS-3000 and Programmable Logic Controller (PLC) by Siemens, Eurotherm, Allen Bradley, Omron and Mitsubishi. And in the Philippines, I worked as Electrical Supervisor for Sewerage Treatment Plant and Palm Oil Refinery Plant.

Through my experiences from start-up & commissioning and maintenance to construction, from Chemical Process Plant, and Palm Oil Refinery Plant to Sewerage Treatment Plant & Pumping Station, it would be fair to say that I’m one of our company assets. I believe my strengths in attaining my maximum productivity with my jobs are; strong teaching skills and strategies, highly motivated, and dedication to my roles and responsibilities. In addition, I always maintain a mature, gracious and professional manner when communicating with people, even when difficulties arise. I have considered this value as the core of my attitude towards effectively working through and with others.

WORK EXPERIENCE

STANLEY CONSULTANTS INC, Doha Qatar

Electrical & InstrumentInspector, May 2009 up to present

Project Name: Pumping Station 70 & Pumping Mains - Doha North Sewerage, Treatment Plant.

Client: Qatar Public Works Authority, Drainage Affairs (ASHGHAL).

ROLES & RESPONSIBILITIES

Pumping Station 70 & Pumping Mains – Doha North Sewerage Treatment Plant are monitored & controlled via SCADA through RTU & PLC.

Site representative for all matters related to construction quality assurance of electrical and instrumentation works. Perform final inspections (RFIA – Request For Inspection & Approval), criteria of acceptance are based on approved drawings & installation standards, approved materials, ITP, method statements and project requirements & standards (contract documents, contract drawings, International Standards, BS standards, Qatar Construction Specification 2007 and KARHAMAA standards). Draft NCR if there is non-compliance and submit to Resident Engineer. Review electrical & instrumentation contractor submittals and forward comments to Senior Electrical Engineer. Prepare worksheets for electrical & instrumentation monthly progress and submit to Senior Schedule Planner and Quantity Surveyor. Prepare daily project report. Carry out monthly electrical safety inspection and make a report. The scope of electrical & instrumentation works of our on-going project arethe following; 11kV metalclad switchgear with 4 No. 7MVA incomers and 10 No. outgoing feeders (Siemens), 4 No. 3.3kV metalclad switchgears (Schneider), 4 No. 3.3kV 2500kVA generators (Detroit engine & Leroy Somer alternator), 8 No. 11/3.3kV 5MVA oil-filled power transformers (Areva TD), 2 No. 11kV/433V 1600kVA oil-filled power transformers (Areva TD), 1 No. 3.3kV/433V 1600kVA oil-filled power transformer (Areva TD), 3.3kV MCCs (Schneider), 10 No. 3.3kV VFD (Siemens), 10 No. 3.3kV soft start units (Mocotech), 10 No. 3.3kV 840kW motors (Siemens) & vibration/temperature monitoring system (skf), 10 No. 3.3kV 740kW motors (Loher) & vibration/temperature monitoring system (skf), 3 No. elevators (Schlindler), 415V MCCs (Siemens), 415V VFDs, 415V motors, submersible pumps, low voltage switchboards, capacitor bank, jib & gantry cranes (Morris), odour control unit & water softener (Siemens), electric shutter doors, HVAC equipments (Mitsubishi & York), lighting & small power system, lightning protection system, earthing & bonding system, high voltage cables (Draka), low voltage cables (Elsewedy), control cables, fiber optic cables, cable tray and ladder system (ICMS), UPS & DC System, SCADA (Siemens), PLC (Siemens), RTU (Siemens), motorized penstocks (Fontaine & Rotork), motorized valves (Glenfield & Rotork), electromagnetic & turbine flowmeters (Khrone), level & pressure transmitters, thermocouple, control valves, fire alarm system and CCTV surveillance.

PROJECT OVERVIEW

Pumping Station 70 is handling raw sewage, electrical & instrumentation equipments at wet wells are classified zone 1 hazardous atmosphere application and degree of protection, IP 68. Pumping Station 70 & Pumping Mains are fully controlled and monitored via SCADA Master Station. The principal elements of Pumping Station 70 and Pumping Mains are the following: Mechanically raked Screen Chamber 36 meters depth housed in a 20 meters outside diameter shaft; Lifting Pumping Station 40 meters depth and 38 meters diameter with 10 numbers pump sets, motor rating of 3.3kV, 740kW motors are arranged to be controlled and started by soft start units; Forwarding Pumping Station at ground level equipped with 10 numbers pump sets, motor rating of 3.3. kV, 840kW motors are arranged to be controlled and started by variable frequency drives; 11 kV & 3.3kV switchgears rooms, 3.3 kV & 415V motor control rooms, 11kV/3.3kV oil-filled power transformer rooms, 11kV/433V & 3.3kV/433V oil-filled power transformer rooms, 3.3 kV generator building, odour control unit, administration building & control room, workshop & fuel tank farm; and Pumping Mains - has 14 kilometers of triple 1600mm diameter ductile iron pipelines to Doha North – Sewerage Treatment Plant with associated flow meter chambers, crossover valve chambers, valve chambers, air valve chambers, washout valve chambers and cable draw pits. Along with the 14 kilometer pipelines are fiber optic cables & LV cables draw-into the UPVC ducts, these cables are connected to RTU and arranged to monitor flow meters and valves and indicate status in the Pumping Station 70 SCADA Master Station.

GULF STABILIZERS INDUSTRIES (CHEMICAL PROCESS PLANT), Jubail, Saudi Arabia

Senior Electrical Technician, September 2003 to March 2009 (5 years + 6 months)

ROLES & RESPONSIBILITIES

Chemical Process Plant, Palletizing Plant, and Tank Farm & Utilities are monitored and controlled via Distributed Control System (DCS) by YOKOGAWA version Centum CS-3000.

Diagnose & repair equipments and control faultsusing various electrical measuring instruments and schematic diagrams, participate in major shutdown, overhaul works and preventive maintenance. Perform daily routine maintenance according to checklist for all electrical transmission equipments such as 34.5kV Gas Insulated Switchgears, 34.5kV Air Insulated Switchgears, 34.5kV/4.16kV oil-filled power transformers; 4.16kV Metalclad Switchgears, 4.16kV/480V oil-filled & dry type transformers, Neutral Ground Resistors, 4.16kV MCC & 480V MCC, UPS & DC System, capacitor bank etc.Review breakdown history in the event log ofprotection relay and deliver maintenance, check & test starter contacts & interlocks and carry out restart and function test.Make reports to equipments that are frequently alarm or fault and suggest corrective actions to supervisor. Ensureelectrical equipments are at the optimum level of reliability and dependability. Log daily and maintain records of energy meter readings.Isolate circuit breakers, rack-out and switch on earthing lever, and lock-out & tag-out before deliveringmaintenance or in case of unexpected breakdown of equipments.Update remaining/consumed spare parts & consumables lists to ensure its availability.Assist and coordinate to supervisor for monthly expense basis on spare parts, consumables, and maintenance cost. Carry out electrical works in accordance with company general safety regulations, permit to work system, lock-out & tag-out procedures prior to commencing work. Follow all safety instructions and notices, wearing personal protective equipment (PPE) at all times, and participate STOP safety programs, emergency response, EHS management system and QMS. Other electrical equipments under my area (process plant, palletizing plant and tank farm & utilities) of responsibility are the following; 4.16kV chillers & its MCC & vibration/temperature monitoring system, process hot oil heater, air compressor units, emergency generators, 480V motors & its MCC, HVAC units, hoist & cranes, extruders, DC motors & its drives & control system (PLC), bagging & wrapping machines etc. Carry out motor winding tests - insulation resistance test (PI or spot test) and line resistance test. Know how to interpret the following diagrams; single line diagram, schematic diagram, control diagram, instrument loop diagram (ILD), and pipe & instrument diagram (P&ID).

COMPANY OVERVIEW

Gulf Stabilizers Industries is the only one local manufacturer of antioxidants (Anox 20, Alkanox 240 & Anox PP 18) in the GCC and polymer additives producing company. It’s an ISO 9001:2000 (QMS) and ISO 14001:2004 (EMS) certified. The business processes in purchase, production, quality, sales, distribution, maintenance, HR, finance and costing are well automated and tightly integrated using SAP ECC 5.00 running in Windows 2003. The plant is built with state of the art technology with Distributed Control System (DCS) by Yokogawa version Centum CS-3000. The plant is composed of Chemical Process Plant, Non Dust Blend/Extrusion/Palletizing Plant, and Utilities & Tank Farms. All electrical equipments in the field are classified explosion proof, zone 1 hazardous atmosphere applications and degree of protection minimum of IP 55.

PROPERTY SPECIALIST TEAM INC, Philippines

Electrical Supervisor, May 2001 to December 2002 (1 year + 6 months)

ROLES & RESPONSIBILITIES

Supervise electrical activities, and diagnose & repair equipments and control faults in the following electrical equipments; 4 No. 2000kVA generators, 4 No. 2000kVA oil-filled power transformers, switchgears, sewerage treatment plant (STP) controls and equipments, 440V MCC, capacitor bank, PLC, multi-stage water turbine pump motors & controls, submersible pump motors and controls, fire pump motors and controls, lighting & small power system, fire alarm system and HVAC equipments. Monitor & assure routine and preventive maintenance are done accordingly. Ensure that all electrical activities are carried out safely and relevant to standard operating procedures. Review electrical purchase requisitions and prepare forecast needed spares/consumables to ensureits availability at the time needed. Record/report accomplishments and status of electrical activities. Make a report for maintenance, spare part & consumable costs and prepare maintenance budget for the whole year.

A. Y. TANTUCO MANUFACTURING INC, Philippines

Electrical Supervisor, November 1999 to March 2001 (1 year + 4 months)

ROLES & RESPONSIBILITIES

Supervise electrical activities, and diagnose & repair equipments and control faults in the following electrical equipments; switchgears, 3 No. 3000kVA oil filled power transformers, PLC, VFDs, DC drives, 440V MCCs, UPS, DC system, thermal oil boilers, steam boilers, chillers, air compressor packages, cooling tower system, capacitor bank, hoist & cranes, and lighting & small power system. Organize all activities of electrical technicians and ensure that all maintenance under their control are carried out safely & relevant to standard operating procedures. Ensure that all electrical technicians carried out their duties correctly. Monitor & ensure routine and preventive maintenance have been done accordingly and ensure that time allocated for maintenance will not exceed, where there is conflict with immediate needs of the plant. Review electrical purchase requisitions and prepare forecast needed spares/consumables to ensure its availability at the time needed. Record/report accomplishments and status of electrical activities. Make a report for maintenance, spare part & consumable costs and prepare maintenance budget for the whole year.

R. C. ELECTRIC CORPORATION, Philippines

Electrical Technician, January 1997 to June 1999 (2 years + 5 months)

ROLES & RESPONSIBILITIES

Installation of the following electrical equipments and controls; PLC, VFD, DC drives, 440V MCC, lighting & small power system, and earthing & bonding system. Cable termination in marshalling panels such as start, stop & indication signals for motors, PLC control cables (input and output signal cables), VFD control cables (reference input, digital outputs, start stop reset enabling signals, reference output for remote display monitor), and DC drives control cables (speed loop controls and speed feedback signal), tachogenerator, encoder and communication cables. Power and control cables’ termination in local control panels, terminal box of motors, and MCCs. Assist testing and commissioning all installed electrical controls, motors and equipments.

ACADEMIC QUALIFICATIONS

Bachelor of Science in Electrical Engineering at the FEATI University, Manila, Philippines (Batch 1998)

PROFESSIONAL LICENSE

Registered Electrical Engineer, Registration number: 0019815, PRC Philippines

Registered Master Electrician, Registration number: 0020514, PRC Philippines

TRAININGS AND SEMINARS

Lock-out & Tag-out Procedure, Working Permit System, Emergency Response, General Safety Rules, Process Safety Management, and ISO 9001:2000 (Gulf Stabilizers Industries, Saudi Arabia)

Electrical Test Instruments Seminar; Hi-pot Tester, AVO Foster-SCITS-100 current injector, AVO Megger BM11D, Fluke 189 True RMS Multitester, Clamp Meter LH 1050 LEM, Tachometer Testo 470 and Digital Thermometer Testo 925 (Gulf Stabilizers Industries, Saudi Arabia)

Fire Fighting using Fire Truck (Royal Commission, Fire Dept., Saudi Arabia)

First Aid/CPR Class (Almana General Hospital, Saudi Arabia)

Fire Prevention & Fire Fighting (ASIA Pacific Maritime Services, Inc.)

Elementary First Aid (ASIA Pacific Maritime Services, Inc.)

Personal Survival Techniques at Sea (ASIA Pacific Maritime Services, Inc.)

PERSONAL DATA

Name:Jessie D. Palma

Birth date:November 5, 1976

Age:34 years old

Nationality:Filipino

Civil Status:Married

Language:English & Tagalog

Height:5’6’’

Weight:72 kg

Page 1 of 4